GENERAL REGULATIONS 

 

This manual is part of the product and we recommend to store it within the close distance of 

the device so it information may be obtained quickly and easily. 

 

The device is not intended to be used for any other usage than it is described in both parts of 

the user and service manuals. 

 

The service should perform regular visual checks of the device condition and provide its basic 

maintenance. 

 

Works  on  the  electric  device  may  by  performed  only  by  the  workers  with  appropriate 

qualification within the meaning of the Regulation ČÚBP and ČBÚ no. 50/1978 Sb and after 

familiarization with the device in the least necessary extent. 

 

Do not expose the device to water of humidity and used it exclusively in accordance with the 

operating  conditions.  Prevent  the  impact  of  significant  fluctuations  of  surrounding 
temperatures at high atmospheric humidity to prevent condensation of water vapour in the 
device. 

 

Prior to any maintenance, unplug all the electric power supply! 

 

In  case  of  a  breakdown  or  a  malfunction,  please  send  the  device  along  with  detailed 

description of the failure back to the distributor. 

 

Keep  the  recommended  value  of  maximum  electric  current  output  load 

  see  the  electric 

data. 

10

 

TECHNICAL DATA 

Power supply of the central unit: 

 

 

230V~/50Hz/3VA 

The thermal resistance of the control unit: 

 

max 50°C

 

Central unit dimensions (including the case): 

 

125 x 95 x 50 mm (l x w x h) 

The method is disposal:  

 

 

 

the device is disposed as sorted waste 

Method of cables attaching: 

 

 

 

wiring connectors 

Resistance of the central unit:   

 

 

IP 40 

Software class: 

A  (the  control  function  are  not  meant  to 
affect safety of the device) 

Содержание REG110

Страница 1: ...User manual Automatic regulation of burning Reg110...

Страница 2: ...ol 5 3 4 Settings screen 5 4 Indication of the proceses of the automatic regulation of burning 6 5 Control procedure of the automatic regulation of burning 6 5 1 Regulation start 6 5 2 Refill the Wood...

Страница 3: ...I External Air Inlet It is possible to install the automatic combustion control in all the fireplace and stove fire chambers with external air inlet 1 2 Advantages of the automatic regulation of burni...

Страница 4: ...down arrow switch to the device settings see Chapter 3 4 Up arrow switches between the current temperature and the position of the EAI damper on the main screen up arrow switch to the manual settings...

Страница 5: ...e settings see Chapter 3 4 SDS is not an adequate replacement for the mechanical door switch it is not recommended to activate it at the installations where the temperature sensor of the combustion pr...

Страница 6: ...with manual control By pressing the button M for the period of 6 sec we will enter the manual control screen MAN manual shows on the screen It is possible to manually set the exact position of the EA...

Страница 7: ...chamber Every start is confirmed by sound signal The regulation start is done either automatically or manually Automatically o if the stove door switch is installed o in case the software door switch...

Страница 8: ...use any aggressive agents or other substance that might damage the machine 8 PRACTICAL PROCEDURE OF THE HEATING WITH THE AUTOMATIC REGULATION OF BURNING Starting It is necessary to execute START of t...

Страница 9: ...and used it exclusively in accordance with the operating conditions Prevent the impact of significant fluctuations of surrounding temperatures at high atmospheric humidity to prevent condensation of...

Страница 10: ...s or on replaced parts 7 Complaints are applicable at the seller where the product was purchased If in the warranty card there is stated different subject meant for repair which is closer to the purch...

Отзывы: