Timpex REG110 Скачать руководство пользователя страница 3

 
Automatic regulation of burning REG110 

 

1

 

DEVICE DESCRIPTION 

1.1

 

General information 

The automatic combustion control optimizes the combustion development in order to increase the 
effectivity of fireplace or stove fire chamber. 
The  automatic  combustion  control  Timpex  is  controlled  by  the  central  unit  with  a  microprocessor, 

which  compares  the  current  combustion  status  with  the  program  “Optimization  of  combustion 
process”  and  based  on  its  assessm

ent  then  regulates  the  air  volume  in  the  fire  chamber  using 

electronically controlled damper EAI (External Air Inlet). 
It is possible to install the automatic combustion control in all the fireplace and stove fire chambers 
with external air inlet. 

1.2

 

Advantages of the automatic regulation of burning 

 

prolongs the combustion process and stoking interval 

 

reduces wood consumption up to 30% 

 

prevents overheating of the heating system 

 

increases the combustion and heating system effectivity 

 

improves thermal comfort 

 

improves heating safety 

 

prolongs working life of the heating system 

 

controls other external components (depends on the control type) 

 

indicates the need of further stoking 

 

informs about the heating system activity  

 

Figure 1: Regulatory curve 

 

Regulatory curve without regulation 

Regulatory curve without regulation 

TEM

PE

RA

TUR

TIME 

Содержание REG110

Страница 1: ...User manual Automatic regulation of burning Reg110...

Страница 2: ...ol 5 3 4 Settings screen 5 4 Indication of the proceses of the automatic regulation of burning 6 5 Control procedure of the automatic regulation of burning 6 5 1 Regulation start 6 5 2 Refill the Wood...

Страница 3: ...I External Air Inlet It is possible to install the automatic combustion control in all the fireplace and stove fire chambers with external air inlet 1 2 Advantages of the automatic regulation of burni...

Страница 4: ...down arrow switch to the device settings see Chapter 3 4 Up arrow switches between the current temperature and the position of the EAI damper on the main screen up arrow switch to the manual settings...

Страница 5: ...e settings see Chapter 3 4 SDS is not an adequate replacement for the mechanical door switch it is not recommended to activate it at the installations where the temperature sensor of the combustion pr...

Страница 6: ...with manual control By pressing the button M for the period of 6 sec we will enter the manual control screen MAN manual shows on the screen It is possible to manually set the exact position of the EA...

Страница 7: ...chamber Every start is confirmed by sound signal The regulation start is done either automatically or manually Automatically o if the stove door switch is installed o in case the software door switch...

Страница 8: ...use any aggressive agents or other substance that might damage the machine 8 PRACTICAL PROCEDURE OF THE HEATING WITH THE AUTOMATIC REGULATION OF BURNING Starting It is necessary to execute START of t...

Страница 9: ...and used it exclusively in accordance with the operating conditions Prevent the impact of significant fluctuations of surrounding temperatures at high atmospheric humidity to prevent condensation of...

Страница 10: ...s or on replaced parts 7 Complaints are applicable at the seller where the product was purchased If in the warranty card there is stated different subject meant for repair which is closer to the purch...

Отзывы: