Timpex REG110 Скачать руководство пользователя страница 5

 
Automatic regulation of burning REG110 

 

3

 

SCREENS DESCRIPTION 

3.1

 

Main screen 

 

 

 

 
 
 
 
 
 
 
 
 

 

 

Indication of the active software door switch 

Shows the activity of SDS 

 the SDS checks the temperature changes of combustion products. 

The SDS is an in-built software, which, based on the temperature changes (decrease or increase) of 
the combustion products in fire chamber, recognizes the add wood or opening of the fire chamber 
door.  For  correct  start  of  regulation  of  burning  with  SDS,  the  door  must  be  open  for  at  least  20 
seconds, when you are putting wood into the fireplace. Based on the temperature change, the SDS 
automatically performs a new start of the combustion control process (see Chapter 5.1). 

 

SDS works both during start the fire and add wood 

o

 

SDS is active during displaying the information on the main screen. 

 

It is possible to turn on/off the SDS in the settings (see Chapter 3.4) 

 
SDS  is  not  an  adequate  replacement  for  the  mechanical  door  switch 

  it  is  not 

recommended  to  activate  it  at  the  installations,  where  the  temperature  sensor  of  the 
combustion products is affected by hot-water or accumulative exchanger. 

 

Current value displayed on the screen 

There are two figures you may view. 

S-1

 

position of the EAI damper 

 you can view this information in percentage from 0 to 

100 (100% = the EAI damper is fully opened and the largest volume of air goes into 
the  fire  chamber,  0%  =  the  damper  is  fully  closed  the  no  air  goes  into  the  fire 
chamber) 

 

T-1

 

current temperature of the combustion products in the 

fire chamber (in °C)

 

3.2

 

The screen with combustion modes 

By pressing the button 

“M” 

for the period of 

3

 sec. we will enter the settings screen. 

F-M

 /fire mode/ shows on the screen 

Current combustion mode is displayed. 

Current value displayed on the 

screen 

Indication of the active 

software door switch 

Indication of the automatic 

control mode 

Indication of the 

manual control mode 

 

Indication of the time delay 

Содержание REG110

Страница 1: ...User manual Automatic regulation of burning Reg110...

Страница 2: ...ol 5 3 4 Settings screen 5 4 Indication of the proceses of the automatic regulation of burning 6 5 Control procedure of the automatic regulation of burning 6 5 1 Regulation start 6 5 2 Refill the Wood...

Страница 3: ...I External Air Inlet It is possible to install the automatic combustion control in all the fireplace and stove fire chambers with external air inlet 1 2 Advantages of the automatic regulation of burni...

Страница 4: ...down arrow switch to the device settings see Chapter 3 4 Up arrow switches between the current temperature and the position of the EAI damper on the main screen up arrow switch to the manual settings...

Страница 5: ...e settings see Chapter 3 4 SDS is not an adequate replacement for the mechanical door switch it is not recommended to activate it at the installations where the temperature sensor of the combustion pr...

Страница 6: ...with manual control By pressing the button M for the period of 6 sec we will enter the manual control screen MAN manual shows on the screen It is possible to manually set the exact position of the EA...

Страница 7: ...chamber Every start is confirmed by sound signal The regulation start is done either automatically or manually Automatically o if the stove door switch is installed o in case the software door switch...

Страница 8: ...use any aggressive agents or other substance that might damage the machine 8 PRACTICAL PROCEDURE OF THE HEATING WITH THE AUTOMATIC REGULATION OF BURNING Starting It is necessary to execute START of t...

Страница 9: ...and used it exclusively in accordance with the operating conditions Prevent the impact of significant fluctuations of surrounding temperatures at high atmospheric humidity to prevent condensation of...

Страница 10: ...s or on replaced parts 7 Complaints are applicable at the seller where the product was purchased If in the warranty card there is stated different subject meant for repair which is closer to the purch...

Отзывы: