Timpex ECO 20 Скачать руководство пользователя страница 5

 
ECO 20 Automatic Regulation of Burning 
 

3

 

MOBILE APP REQUIREMENTS 

3.1

 

Android Devices 

 

Android 5 “Lollipop“ or newer Android OS

 

 

Bluetooth LE 

 

GPS module 

 
The app is available on Google Play under the name 

Timpex ECO

 
 
 
QR Code for download: 
 
 
 
 
 

3.2

 

Apple iOS Devices 

 

Apple iOS 11 or newer 

 

Bluetooth LE 

 

GPS module 

 
The app is available on the App Store under the name 

Timpex ECO

 

 
 
 

QR Code for download: 

 
 
 
 
 
 

The app communicates with the control unit using your phone’s Bluetooth connection.

 

The app syncs data with the control unit every 10 seconds. 

 

 

Содержание ECO 20

Страница 1: ...USER MANUAL Automatic Regulation of burning for fireplace stoves ECO 20...

Страница 2: ...TION 6 5 1 Main Screen 6 5 2 Menu 8 6 CONTROL UNIT SOUND ALERTS 11 7 USING AUTOMATIC REGULATION OF BURNING 11 7 1 Start 11 7 2 Refueling 12 8 SAFETY INSTRUCTIONS 12 8 1 What to Do in Case of Power Out...

Страница 3: ...el in the next refueling The mobile app informs the user about the current status throughout the entire burn process Based on the current firebox temperature the app displays 3 color indicators yellow...

Страница 4: ...rning has a microprocessor based control unit which compares the current situation in the firebox with a Combustion Optimization program depending on the results the system adjusts the airflow to the...

Страница 5: ...ailable on Google Play under the name Timpex ECO QR Code for download 3 2 Apple iOS Devices Apple iOS 11 or newer Bluetooth LE GPS module The app is available on the App Store under the name Timpex EC...

Страница 6: ...arches for your specific ECO 20 control unit only near your position 4 Once launched the app starts an automatic search for nearby ECO 20 devices Once the search completes the app will show a list of...

Страница 7: ...n current firebox temperature yellow firebox temperature below optimum should only show when starting a fire or when down to hot coals green firebox at optimum temperature best fuel efficiency shows a...

Страница 8: ...ettings see Menu below Burning phase circle Maximum burn point A Refueling point with sound alert B START button Press to start a new automatic burn control cycle Details see Start Burn Control below...

Страница 9: ...ly using its attached handle or the stove s own shutter handle can be used When automatic control is off the Main Screen shows MAN for manual mode Current flue gas temperature Current temperature of f...

Страница 10: ...rature to shutter position in a different way The factory setting is no 3 which should work well with most fireboxes If your firebox generally burns too hot using program 3 step down to program 2 or f...

Страница 11: ...is 58 Celsius contacts open when T2 temperature readout drops 3 Celsius below the preset value integrated overheating protection if water temperature in heat exchanger reaches 90 Celsius the control u...

Страница 12: ...ueled EAI shutter open to 100 o 3 short beeps Firebox door open too long left open or partly open o 3 long beeps every 3 minutes Request to refuel o 1 long beep 4 medium length beeps Going to standby...

Страница 13: ...the outage However unless you have purchased the return spring shutter option keep in mind that the air intake shutter will have remained in whatever position it was in before power failed If you sub...

Страница 14: ...rature has been reached automatic regulation of burning starts The program ensures optimal combustion and maximizes heating efficiency Once the firebox reaches maximum temperature the app background s...

Страница 15: ...s These are in this case incorrect and should be ignored The app fails to connect to the control unit First make sure that your device meets the app s software requirements Second verify that no other...

Страница 16: ...Celsius contact with water or excessive humidity Only use the unit within its operating parameters Do not expose the unit to a combination of high humidity and large temperature swings which may cause...

Страница 17: ...An optional sensor for a more reliable auto start function Unlike with the SDS which has a time delay the Magnetic Door Sensor automatically starts a new burn control cycle immediately when the firebo...

Отзывы: