![Timpex ECO 20 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/timpex/eco-20/eco-20_user-manual_1118281010.webp)
ECO 20 Automatic Regulation of Burning
9
Connected unit
Shows the type of control unit the app is currently connected to.
Tap this item to disconnect the app from the current control unit.
This is useful when you want to connect your mobile device to a different Timpex control unit.
Firmware version
Shows the firmware version of the control unit connected to the app.
A text notification is shown by this item when a new firmware version is available for your
control unit. We recommend updating the firmware whenever available to ensure your control
unit remains up to date.
Application version
Displays the software version number of the mobile app.
We recommend checking for app updates regularly through Google Play (Android) or the App
Store (Apple), or setting the app to auto-update.
Unit Settings
Here you can configure the control unit for your firebox and perform some maintenance tasks.
The Settings menu is password-protected; the default password is
1234
.
Contents
•
Program setting
-
Allows you to select one of a number of pre-set control curves, each of which
maps exhaust temperature to shutter position in a different way. The factory
setting is no. 3, which should work well with most fireboxes.
-
If your firebox generally burns too hot using program 3, step down to program 2 or
further down to 1.
-
If the firebox generally burns too cool, raise the setting to program 4 or 5.
•
Software door sensor /SDS/
-
The SDS bypasses the need to push START in the app when beginning a new burn
cycle.
-
The SDS is a software algorithm that monitors the changes of current exhaust
temperature, from which it can infer that fuel was added and / or the firebox door
was opened, and start a new burn control cycle accordingly.
-
When using the SDS feature to auto-start the burn cycle,
keep the firebox door
slightly open after refueling until the control unit sounds an alert
(3 short beeps).
-
The sensitivity of the SDS algorithm to temperature changes can be calibrated in
steps from 1 to 5.
o
The factory default setting is 3.
o
If you would like the SDS to be more sensitive to temperature changes,
increase the value to 2 or further up to 1.
o
If you want the SDS to be less sensitive, lower the value to 4 or 5.
•
Test
-
Test the functionality of the automatic regulation system. Click an item to test EAI
shutter open / close, sound alerts, relay contacts on / off, and (when installed)
color LED function.