ECO 20 Automatic Regulation of Burning 
 

15 

 

Try press START button. If the sensor problem has resolved itself, a new burn cycle should 
continue normally without the need for you to do anything. If it does not, check the 
thermal sensor for bad wiring and / or damage. 

 
 

11

 

GENERAL NOTICES 

 

This Manual is an integral part of your purchase; we recommend storing it near the device so 
as to have it available for reference when needed. 

 

The  device  is  not  designed  for  any  use  other  than  those  described  in  the  User and  Service 
Manuals. 

 

The operator should regularly visually check the condition of the device and provide basic care 
and maintenance. 

 

Do  not  expose  the  control  unit  to  temperatures  over  50  Celsius,  contact  with  water  or 
excessive humidity. Only use the unit within its operating parameters. Do not expose the unit 
to a combination of high humidity and large temperature swings, which may cause water vapor 
to condense inside and damage the unit. 

 

Disconnect all electrical connections before performing any maintenance on the device! 

 

In the event of malfunction, please return the device to the distributor, along with a detailed 
description of the problem. 

12

 

TECHNICAL DATA 

 

Control unit input power 

 

5V/DC,

 

50Hz 0,3A 

 

Control unit heat resistance 

 

max 50°C

 

 

Temperature sensor heat resistance 

iron part 

max 700 °C

 

 

Type of temperature sensor T1  

thermocouple 

  type K 

 

Typ teplotního čidla T2

  

 

resistance sensor 

 type PTC 

 

Disposal method 

 

 

dispose of as separate waste 

 

Cable attachment method 

 

konektorové zapojení

 

 

Control unit IP   

 

 

IP 40 

 

Software class   

 

 

A (control functions do not affect device safety) 

 

 

Содержание ECO 20

Страница 1: ...USER MANUAL Automatic Regulation of burning for fireplace stoves ECO 20...

Страница 2: ...TION 6 5 1 Main Screen 6 5 2 Menu 8 6 CONTROL UNIT SOUND ALERTS 11 7 USING AUTOMATIC REGULATION OF BURNING 11 7 1 Start 11 7 2 Refueling 12 8 SAFETY INSTRUCTIONS 12 8 1 What to Do in Case of Power Out...

Страница 3: ...el in the next refueling The mobile app informs the user about the current status throughout the entire burn process Based on the current firebox temperature the app displays 3 color indicators yellow...

Страница 4: ...rning has a microprocessor based control unit which compares the current situation in the firebox with a Combustion Optimization program depending on the results the system adjusts the airflow to the...

Страница 5: ...ailable on Google Play under the name Timpex ECO QR Code for download 3 2 Apple iOS Devices Apple iOS 11 or newer Bluetooth LE GPS module The app is available on the App Store under the name Timpex EC...

Страница 6: ...arches for your specific ECO 20 control unit only near your position 4 Once launched the app starts an automatic search for nearby ECO 20 devices Once the search completes the app will show a list of...

Страница 7: ...n current firebox temperature yellow firebox temperature below optimum should only show when starting a fire or when down to hot coals green firebox at optimum temperature best fuel efficiency shows a...

Страница 8: ...ettings see Menu below Burning phase circle Maximum burn point A Refueling point with sound alert B START button Press to start a new automatic burn control cycle Details see Start Burn Control below...

Страница 9: ...ly using its attached handle or the stove s own shutter handle can be used When automatic control is off the Main Screen shows MAN for manual mode Current flue gas temperature Current temperature of f...

Страница 10: ...rature to shutter position in a different way The factory setting is no 3 which should work well with most fireboxes If your firebox generally burns too hot using program 3 step down to program 2 or f...

Страница 11: ...is 58 Celsius contacts open when T2 temperature readout drops 3 Celsius below the preset value integrated overheating protection if water temperature in heat exchanger reaches 90 Celsius the control u...

Страница 12: ...ueled EAI shutter open to 100 o 3 short beeps Firebox door open too long left open or partly open o 3 long beeps every 3 minutes Request to refuel o 1 long beep 4 medium length beeps Going to standby...

Страница 13: ...the outage However unless you have purchased the return spring shutter option keep in mind that the air intake shutter will have remained in whatever position it was in before power failed If you sub...

Страница 14: ...rature has been reached automatic regulation of burning starts The program ensures optimal combustion and maximizes heating efficiency Once the firebox reaches maximum temperature the app background s...

Страница 15: ...s These are in this case incorrect and should be ignored The app fails to connect to the control unit First make sure that your device meets the app s software requirements Second verify that no other...

Страница 16: ...Celsius contact with water or excessive humidity Only use the unit within its operating parameters Do not expose the unit to a combination of high humidity and large temperature swings which may cause...

Страница 17: ...An optional sensor for a more reliable auto start function Unlike with the SDS which has a time delay the Magnetic Door Sensor automatically starts a new burn control cycle immediately when the firebo...

Отзывы: