![Timken Rollon Tecline Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/timken/rollon-tecline/rollon-tecline_use-and-maintenance_1118193029.webp)
Tecline
UM-29
ATTENTION!
For instructions on routine and special
maintenance and for the safety informa-
tions about the “Rod Lock” safety system,
refer to the specific assembly manual of
the accessory in question.
a. Lock the plate by placing it on its lower mechanical stop
without removing pneumatic pressure to the rod locking
unit (Q).
b. Remove plugs (A) using the correct removal tool.
c. Unscrew the fixing screws (B), and remove the plate (C)
with the security system still mounted.
d. Undo socket head cap screws (D) on the plate (C) opposite
to the shutter.
e. Extract the shutter (after removing its pneumatic compo-
nent) and replace it with a new one.
f. Perform the operation in reverse for refitting.
Removal and replacement of the stopper cylinder security system (optional)
ATTENTION!
For instructions on routine and special
maintenance and for the safety informa-
tions about the “Stopper Cylinder” safety
system, refer to the specific assembly
manual of the accessory in question.