7
3.
TECHNICAL DATA
If your application is out of the specification range shown in this diagram, please contact your local
distributor. Timken cannot be held liable for these applications.
Example:
1.
The application temperature is +41° F/+5° C. What is the maximum tube length allowed for
standard grease?
Correct Answer: 3 m maximum tube length for standard grease, 5 m maximum tube length for low
temperature grease (arrow 1 meets the dashed line of the standard grease range at 3 m).
2.
You want to use a 4 m tube. Up to which temperature can the system be used?
Correct Answer: 50° F/+10° C with standard grease 23° F/-5° C with low temperature grease
(arrow 3 meets the dotted line of low temperature grease at the -5° C mark; and the dashed line
of the standard grease at the +10° C mark).
Table 1
Figure 1
Содержание C-POWER 250