TLR401 Administration
12
4.2 Basics
The TLR401 is manufactured in two versions:
1. TLR401 with built-in biometrical sensor and keypad
2. TLR401-iCLASS with built-in biometrical sensor and embedded iCLASS reader
The TLR401 identifies authorized users by scanning their fingerprints (and optionally their
PINs and iCLASS cards). Successful identification sends a trigger signal to an access
controller within a protected area and is followed by a door lock or release.
The TLR401-iCLASS reads fingerprints and iCLASS cards alternatively.
Fingerprint authentication requires that the authorized user's fingerprints have been enrolled
in advance and that they have been linked to a unique User ID.
Enrollment can be performed on the TLR401, which stores the collected data (Templates).
The 'Template on Card' mode allows you to write Templates onto iCLASS cards (currently
16k2 cards only).
The TLR401 can either be run using the RS485 interface or the Wiegand output:
RS485 Configuration
Running the reader using the RS485 interface means that
administration of the TLR401 is done on the NEXTOR Series
access controller.
All administrator functions, except for enrollment, are disabled
on the TLR401.
Fingerprint Templates are managed by the access controller
and can be distributed to the connected TLR401 readers.
Wiegand Configuration
All administrator functions described in this manual, except for
enrollment, only apply to the Wiegand configuration. All settings
are entered on the keypad of the TLR401.
Fingerprint templates are stored on the TLR401 and cannot be
distributed to connected TLR401 readers.
4.3 Basic Operating Principles
General
Pressing any key triggers a beep.
Release
Beep tone and all LEDs flashing green
Green and Red / Green LEDs
Guides an administrator through the setup menus
Red LEDs and Beeps
Generally indicates an error
Error Message
3 short beeps and all LEDs flashing red 3 times indicate an error.
The desired function was not performed.
3x Key "#"
Press "#" three times to reset the reader to keypad default state after typing
errors or wait for timeout (10-30 seconds, depending on status) to return to the default
position.