6
7
9. The programmes and clock time can now be set.
If display was blank prior to switching on power,
allow the battery to charge for at least 2 to 4
hours prior to programming.
10. Replace transparent front cover.
5b Panel Mounting
1. Remove the base plate and terminal cover
as described for wall mounting.
2. Install the timeswitch in a 68mm square hole
previously cut in the panel.
3. Lock the timeswitch in position using the panel
mounting bracket supplied.
4. For mains switching (230V AC 50Hz) connect the
supply to the terminals according to the wiring
diagram noting that a link is required between
terminals 2 and 8, this is due to the option of
having voltage free contacts (see fig 2). Refer to
(fig 3) for voltage free contacts wiring. Ensure that
all bare conductors are sleeved and that correct
polarity is observed.
5. Re-tighten the fixing screws attached to the face
of the unit to the base plate.
6. Switch on the power from the supply line.