4-6
29084-05 03/17
VERSALIFT VST-7500-I
OPERA
TION
Tool Power Controls
Figure 4.3
LOWER CONTROL OPERATION
DANGER:
DEATH OR SERIOUS INJURY
MAY RESULT IF CHASSIS BECOMES
ENERGIZED. DO NOT OPERATE THE AERIAL
DEVICE WHILE CREATING A PATH TO THE
GROUND.
The Lower Controls are located on the turret as shown
Figure 4.4. The detented control selector is used to
select operation of the aerial lift from the upper or
lower controls, this also serves as the emergency
stop for the upper controls. When a control station is
selected the other is one inoperable. The remaining
control levers at the lower control station are spring-
loaded. The lower control decal identifies the function
of each control lever and indicates which direction to
move the control lever for the desired movement. When
released the control lever will return to the centered or
neutral position and motion ceases.
ELECTRIC SELECTOR STATION
- The electric
controls are also part of lower control station mounted
on turret. A description of each control and the
method of operation is given below.
ENGINE START/STOP CONTROL (Standard)
- The
engine start/stop control is convenient for the ground
crew at the turret. The engine start/stop control is
operated by a three-position toggle switch.
To start the engine from the turret
, push the toggle
to the “START/STOP” position and hold the toggle in
that position for a moment until the engine starts.
Allow the toggle to return to the neutral or centered
position.
To stop the engine from the turret
, push the toggle
to “START/STOP” again. Allow the toggle to return to
the neutral or centered position. Refer to Chapter 5,
“Emergency Operation” for information on the use of
this control in an emergency.
Lower Controls at Turret
Figure 4.4
TWO-SPEED MANUAL THROTTLE CONTROL
(Standard)
- Gives the operator a choice of efficient,
economical engine idle speed or higher engine speed
when faster lift movements are required. Slow speed
also provides the proper hydraulic flow for most
hydraulic tools. The two-speed throttle control will
operate only if the master control is activated. The
two-speed throttle control is operated by a three-
position toggle switch at the turret.
To speed up the engine from the turret
, push the
toggle to the “ENGAGE” position. Allow the toggle to
return to the neutral or centered position.
To slow the engine to an idle from the turret
,
push the toggle to the “DISENGAGE” position. Allow
the toggle to return to the centered or neutral position.
BACKUP PUMP CONTROL (Option)
- If the aerial
lift main power source fails, the backup pump option
can be activated to operate the lift. The backup pump
control is a detented toggle switch located at the turret.
The backup pump system should not be operated
longer than 30 seconds continuously.
Continuous
use will drain the battery and damage (over heat) the
backup pump motor.
To activate the backup pump from the turret
, push
Содержание VERSALIFT VST-7500-I
Страница 2: ......
Страница 4: ......
Страница 6: ......
Страница 8: ...1 2 29084 05 03 17 VERSALIFT VST 7500 I INTRODUCTION Figure 1 1 Model VST 7500 I Nomenclature...
Страница 11: ...2 3 29084 05 03 17 VERSALIFT VST 7500 I RESPONSIBILITIES SAFETY...
Страница 12: ...2 4 RESPONSIBILITIES SAFETY 29084 05 03 17 VERSALIFT VST 7500 I...
Страница 13: ...2 5 29084 05 03 17 VERSALIFT VST 7500 I RESPONSIBILITIES SAFETY...
Страница 24: ...3 6 29084 05 03 17 VERSALIFT VST 7500 I SPECIFICATIONS...
Страница 25: ...3 7 29084 05 03 17 VERSALIFT VST 7500 I SPECIFICATIONS...
Страница 27: ...3 9 29084 05 03 17 VERSALIFT VST 7500 I SPECIFICATIONS...
Страница 28: ......
Страница 42: ......
Страница 50: ...6 4 29084 05 03 17 VERSALIFT VST 7500 I DAILY VISUAL INSPECTION...
Страница 51: ...6 5 29084 05 03 17 VERSALIFT VST 7500 I DAILY VISUAL INSPECTION...
Страница 52: ...6 6 29084 05 03 17 VERSALIFT VST 7500 I DAILY VISUAL INSPECTION...