i  Remove the back box from the external 

intercom in the following way. Insert a 
small screwdriver blade in the end cap 
screwdriver notch (fi g 4, i) and lever 
end cap so that it slides outwards from 
the main case (in opposite directions to 
those shown in fi g 4, iv). Remove the two 
fi xing screws (as shown in fi g 4, iii) and 
remove the back box from the rear of the 
external intercom.

ii  This is a convenient time to mark the 

nameplate(s).

  Referring to fi gs 5i and 5iii push catches 

at each end of the transparent housing 
inwards as shown in fi g 5iii and remove 
ring burtton and nameplate assembly 
followed by the nameplate transparent 
cover, fi nally levering out the nameplate 
as required.

  Mark the nameplate as required with a 

permanent fi bre-tipped pen. When dry 
insert the name plate in its transparent 
cover, ensuring it is the right way up.

  Snap the transparent cover into the 

housing bearing in mind it is not 
symmetrical and the end with the thicker 
lip goes at the end closest to the ring 
button switch.

  Offer the transparent housing to the 

external intercom casing ensuring wiring 
is not trapped and snap the catches into 
place.

  Check the ring button and the nameplate 

are correctly located.

  Repeat for second ring button and 

nameplate assembly if necessary.

Fig 4
i

X = wire to the inside intercom 
 

(2 for DCA2) 

 
Y = wire to door catch (if required)

End plate

Screwdriver 
notch

ii

iii

iv

End cover

End cover

Wiring slot

DCA1_DCA2_Instructs_1.4.indd   6

DCA1_DCA2_Instructs_1.4.indd   6

30/1/07   11:00:35 am

30/1/07   11:00:35 am

Содержание DCA1

Страница 1: ...INSTALLATION OPERATING INSTRUCTIONS AUDIO DOOR ENTRY SYSTEM Model DCA1 Single Channel DCA2 Twin Channel DCA1 DCA2 DCA1 2...

Страница 2: ...al dwellings with a common entrance The DCA1 calls one Connecting cables between component parts are all 2 core so existing bell flex can be used to connect the internal and external units if desired...

Страница 3: ...3 Cable channel Note For single channel operation ignore second channel internal intercom and its 2 core connecting cable to terminals 3 and 4 on the external intercom Internal intercom first channel...

Страница 4: ...gnificantly above or below average height then a different mounting height may be considered appropriate The external intercom should be sited in an area away from driving rain and surface water out o...

Страница 5: ...d A further 2 core cable 13 0 2 bell flex will be required if extension beyond 15m is necessary between the external intercom and the second internal intercom for the DCA2 4 Fixing Intercoms 4 1 Exter...

Страница 6: ...the nameplate transparent cover finally levering out the nameplate as required Mark the nameplate as required with a permanent fibre tipped pen When dry insert the name plate in its transparent cover...

Страница 7: ...DCA2 shown Fig 5ii Side view of length of nameplate Fig 5iii Transparent housing Ring button switch Catch Transparent housing Push catch inwards PCB This thicker end goes closest to ring button switch...

Страница 8: ...asily by all potential users If one person usually in one location will be the main user it may be considered appropriate to locate the internal intercom within reach of that person Mark out two holes...

Страница 9: ...om 6 Do s and Dont s 1 Never use the product if it shows any signs of damage 2 In case of damage to the product unplug the mains adaptor from the mains supply to avoid any possibility of electric shoc...

Страница 10: ...orking Check cable between external intercom and door catch for breaks or damage Check that terminations are correctly made at each end of the above cable Check that the mains adaptor is plugged in an...

Страница 11: ...witch Door catch Max 12V DC 1A 3 Year Guarantee In the unlikely event of this product becoming faulty due to defective material or manufacture within 3 years of the date of purchase please return it t...

Страница 12: ...11 For a product brochure please contact Timeguard Ltd Victory Park 400 Edgware Road London NW2 6ND 020 8452 1112 or email csc timeguard com HELPLINE 020 8450 0515 67 058 232...

Отзывы: