background image

10

9. Specifi cations

Mains adaptor:  

 

230V 50Hz/15V, 1A

Maximum interconnect length between 
internal and external intercoms:  

70m (13/0.2 bell fl ex)

Power consuption  

Standby: 

3W

 In 

operation: 

10W

Operating temperature: 

 

-10°C to +50°C

Ringtone volume: 

 

80dBA at 0.3m maximum

 

 

(adjustable by 2 position 

  

slide 

switch)

Door catch: 

 

Max 12V DC 1A

3 Year Guarantee

In the unlikely event of this product becoming faulty due to defective material 
or manufacture within 3 years of the date of purchase, please return it to your 
supplier in the fi rst year with proof of purchase and it will be replaced free of 
charge. For years 2 and 3 or any diffi culty in the fi rst year telephone the helpline 
on 

020 8450 0515.

Recycling

When service life is over please consult your local 
authority regarding method of disposal.

DCA1_DCA2_Instructs_1.4.indd   11

DCA1_DCA2_Instructs_1.4.indd   11

30/1/07   11:00:36 am

30/1/07   11:00:36 am

Содержание DCA1

Страница 1: ...INSTALLATION OPERATING INSTRUCTIONS AUDIO DOOR ENTRY SYSTEM Model DCA1 Single Channel DCA2 Twin Channel DCA1 DCA2 DCA1 2...

Страница 2: ...al dwellings with a common entrance The DCA1 calls one Connecting cables between component parts are all 2 core so existing bell flex can be used to connect the internal and external units if desired...

Страница 3: ...3 Cable channel Note For single channel operation ignore second channel internal intercom and its 2 core connecting cable to terminals 3 and 4 on the external intercom Internal intercom first channel...

Страница 4: ...gnificantly above or below average height then a different mounting height may be considered appropriate The external intercom should be sited in an area away from driving rain and surface water out o...

Страница 5: ...d A further 2 core cable 13 0 2 bell flex will be required if extension beyond 15m is necessary between the external intercom and the second internal intercom for the DCA2 4 Fixing Intercoms 4 1 Exter...

Страница 6: ...the nameplate transparent cover finally levering out the nameplate as required Mark the nameplate as required with a permanent fibre tipped pen When dry insert the name plate in its transparent cover...

Страница 7: ...DCA2 shown Fig 5ii Side view of length of nameplate Fig 5iii Transparent housing Ring button switch Catch Transparent housing Push catch inwards PCB This thicker end goes closest to ring button switch...

Страница 8: ...asily by all potential users If one person usually in one location will be the main user it may be considered appropriate to locate the internal intercom within reach of that person Mark out two holes...

Страница 9: ...om 6 Do s and Dont s 1 Never use the product if it shows any signs of damage 2 In case of damage to the product unplug the mains adaptor from the mains supply to avoid any possibility of electric shoc...

Страница 10: ...orking Check cable between external intercom and door catch for breaks or damage Check that terminations are correctly made at each end of the above cable Check that the mains adaptor is plugged in an...

Страница 11: ...witch Door catch Max 12V DC 1A 3 Year Guarantee In the unlikely event of this product becoming faulty due to defective material or manufacture within 3 years of the date of purchase please return it t...

Страница 12: ...11 For a product brochure please contact Timeguard Ltd Victory Park 400 Edgware Road London NW2 6ND 020 8452 1112 or email csc timeguard com HELPLINE 020 8450 0515 67 058 232...

Отзывы: