venting

2.0 venting

!

WARNING

• 

Risk of fi re. Maintain specifi ed air space clearances to vent pipe and appliance.

• 

The vent system must be supported every 3’(0.9m) for both vertical and horizontal runs. Use support ring assembly W010-
0067 or equivalent non-combustible strapping to maintain the minimum clearance to combustibles for both vertical and 
horizontal runs. Spacers are attached to the inner pipe at predetermined intervals to maintain an even air gap to the outer 
pipe. This gap is required for safe operation. A spacer is required at the start, middle, and end of each elbow to ensure this 
gap is maintained. These spaces must not be removed.

This appliance uses a 4” (102mm) exhaust / 7” (178mm) air intake vent pipe system. Refer to the section applicable 
to your installation.

For safe and proper operation of the appliance, follow the venting instructions exactly. Deviation from the minimum vertical 
vent length can create diffi culty in burner start-up and/or carboning. Under extreme vent confi gurations, allow several minutes 
(5-15) for the fl ame to stabilize after ignition. Although not a requirement, it is recommended for vent lengths that pass through 
unheated spaces (attics, garages, crawl spaces) be insulated with the insulation wrapped in a protective sleeve to minimize 
condensation. Provide a means for visually checking the vent connection to the appliance after the appliance is installed. Use a 
fi restop, vent pipe shield or attic insulation shield when penetrating interior walls, fl oor or ceiling.

The vent terminal may be painted with a high temperature paint to match exterior colours. Use an outdoor paint suitable for 
400°F (200°C). Application and performance of paint is the consumer’s responsibility. Spot testing is recommended.

For vent systems that provide seals on the inner exhaust fl ue, only the outer air intake joints must be sealed using a red high 
temperature silicone (RTV). This same sealant may be used on both the inner exhaust and outer intake vent pipe joints of all 
other approved vent systems except for the exhaust vent pipe connection to the appliance fl ue collar which must be sealed 
using the black high temperature sealant Mill Pac. High temperature sealant must be ordered separately.

For optimum fl ame appearance and appliance performance, keep the vent length and number of elbows to a minimum. 

The air terminal must remain unobstructed at all times. Examine the air terminal at least once a year to verify that 
it is unobstructed and undamaged.

Rigid and fl exible venting systems must not be combined. Different venting manufacturer components must not 
be combined.

These vent kits allow for either horizontal or vertical venting of the appliance. The maximum allowable horizontal run is 20 
feet (6.1m). The maximum allowable vertical vent length is 40 feet (12.2m). The maximum number of vent connections is two 
horizontally or three vertically (excluding the appliance and the air terminal connections) when using fl exible venting.

Horizontal runs may have a 0” rise per foot or 0mm rise per meter however for optimum performance it is recommended 
that all horizontal runs have a minimum 1/4” rise per foot or 21mm rise per meter using fl exible venting. For safe and proper 
operation of the appliance, follow the venting instructions exactly.  

Venting
System

Starter Adapter Part Number

Supplier

Website

Duravent

W175-0053

Wolf Steel

www.duravent.com

Amerivent

4DSCB-N1 (stoves)
4DSC-N2 (fi replaces)

American Metal

www.americanmetalproducts.com

Direct Temp

4DT-AAN

Selkirk 

www.selkirkcorp.com

SureSeal

4DNA

Metal-Fab

www.mtlfab.com

Use only Wolf Steel, Simpson Dura-Vent, Selkirk Direct Temp, American Metal Amerivent or Metal-Fab venting components. 
Minimum and maximum vent lengths, for both horizontal and vertical installations, clearances from vent pipes to combustibles 
and air terminal locations as set out in this manual apply to all vent systems and must be adhered to. For Simpson Dura-Vent, 
Selkirk Direct Temp, American Metal Amerivent and Metal-Fab, follow the installation procedure provided with the venting 
components or on the website for your venting supplier. 
A starter adaptor must be used with the following vent systems and may be purchased from the corresponding supplier: 

note:

If for any reason the vent air intake system is disassembled, re-install per the instructions provided for the initial installation.

This appliance must be installed with a continuous connection of exhaust and air intake vent pipes. Utilizing alternate 
constructions such as a chimney as part of the vent system is not permitted.

This template must be used in conjunction with templates 7.1.1 or 7.1.2, depending on 
termination shape (i.e. round, or round and square). See appropriate templates folder. 

GDS924N

When using Wolf Steel venting components, use only approved Wolf Steel rigid / fl exible components with the following 
termination kits: wall terminal kit 

GD-222

GD-222R

ST47U

 or 1/12 to 7/12 pitch roof terminal kit 

GD-110

, 8/12 to 12/12 

roof terminal kit 

GD-111

, fl at roof terminal kit 

GD-112

 or periscope kit 

GD-201

 (for wall penetration below grade). With fl exible 

venting, in conjunction with the various terminations, use either the 5 foot (1.5m) vent kit 

GD-220

 or the 10 foot (3.1m) vent kit 

GD-330

. For stoves only: wall terminal kit 

GD-175

 (venting included).

Содержание TDS20 Series

Страница 1: ...any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier ca...

Страница 2: ...t burns A physical barrier is recommended if there are at risk individuals in the house To restrict access to an appliance or stove install an adjustable safety gate to keep toddlers young children an...

Страница 3: ...anemia those under the in uence of alcohol those at high altitudes are more affected by carbon monoxide than others Failure to keep the primary air opening s of the burner s clean may result in sooti...

Страница 4: ...ustibles 24 Batteries must be disposed of according to the local laws and regulations Some batteries may be recycled and may be accepted for disposal at your local recycling center Check with your mun...

Страница 5: ...to be located should be considered If possible you should choose a location where the vent will pass through the house without cutting a oor or roof joist This appliance is approved for closet or rec...

Страница 6: ...trical Code in Canada or the ANSI NFPA 70 National Electric Code in the United States In the case where the blower is equipped with a power cord it must be connected into a properly grounded receptacl...

Страница 7: ...on pour les sp ci cations d vacuation Il est n cessaire de bien r installer et resceller l vacuation apr s avoir executer l entretien du syst me de prise d air Serial Number N de S rie W385 XXXX REFER...

Страница 8: ...W415 2884 A 09 21 20 EN 8 general information 1 5 dimensions 25 3 8 645mm SAFETY SCREEN 18 1 2 470mm 24 610mm 19 1 4 4 102mm 7 178mm 489mm 9 5 8 245mm...

Страница 9: ...mbined Different venting manufacturer components must not be combined These vent kits allow for either horizontal or vertical venting of the appliance The maximum allowable horizontal run is 20 feet 6...

Страница 10: ...minate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings Local codes or regulations may require different clearances Do not all...

Страница 11: ...ble See illustrations below It is recommended to maintain a 6 152mm rise 24 61cm maximum Use the periscope kit to locate the air termination above grade The periscope must be installed so that when na...

Страница 12: ...hang N 16 40 6cm 16 40 6cm Clearance above the roof O 2 0 6m 2 0 6m Clearance from an adjacent wall including neighbouring buildings P 8 2 4m 8 2 4m Roof must be non combustible without openings Q 3 0...

Страница 13: ...and is shown in the formula as 45 and 90 respectively or 135 when combined for 45 exit only For the following symbols used in the venting calculations and examples are greater than equal to or greater...

Страница 14: ...gurations requiring more than two 90 elbows the following formulas apply Formula 1 HT VT Formula 2 HT VT 40 feet 12 2m Example V1 8 FT 2 4m VT V1 8 FT 2 4m H1 2 5 FT 0 8m H2 2 FT 0 6m HR H1 H2 2 5FT...

Страница 15: ...7 5m Example V1 4 FT 1 2m V2 1 5 FT 0 5m VT V1 V2 4FT 1 2m 1 5FT 0 5m 5 5 FT 1 7m H1 2 FT 0 6m H2 1 FT 0 3m H3 1 FT 0 3m H4 1 5 FT 0 5m HR H1 H2 H3 H4 2FT 0 6m 1FT 0 3m 1FT 0 3m 1 5FT 0 5m 5 5 FT 1 7...

Страница 16: ...2 2m Example V1 5 FT 1 5m V2 10 FT 3 1m VT V1 V2 5 FT 1 5m 10 FT 3 1m 15 FT 4 6m H1 3 FT 0 9m H2 2 5 FT 0 8m HR H1 H2 3FT 0 9m 2 5FT 0 8m 5 5 FT 1 7m HO 03 one 45 three 90 elbows 135 03 45 270 135 5 4...

Страница 17: ...35 5 4 FT 1 6m HT HR HO 8FT 2 4m 5 4FT 1 6m 13 4FT 4 1m HT VT 13 4FT 4 1m 2 5FT 0 8m 15 9FT 4 8m Formula 1 HT 3VT 3VT 3FT 0 9m x 2 5FT 0 8m 7 5FT 2 3m 13 4 FT 4 1m 7 5 FT 2 3m Since this formula is no...

Страница 18: ...t pipe may cause re For gas stoves only If the appliance is installed directly on carpeting vinyl tile or other combustible material other than wood ooring the appliance shall be installed on a metal...

Страница 19: ...clearance to combustibles Once the vent pipe is installed in its nal position apply red RTV silicone W573 0002 not supplied between the pipe and the restop assembly C In the attic slide the vent pipe...

Страница 20: ...e weather tight by sealing with caulking not supplied D If more vent pipe needs to be used to reach the replace couple them together as illustrated The vent system must be supported approximately ever...

Страница 21: ...intake ex liner and the exhaust collar must be connected to the exhaust exible liner Both Simpson Duravent and Selkirk co linear to co axial adaptors have been approved on this appliance Follow vent...

Страница 22: ...g over the air terminal connector leaving a min 3 4 19mm of the air terminal connector showing above the top of the ashing Slide the ashing underneath the sides and upper edge of the shingles Ensure t...

Страница 23: ...Ensure that a continuous gas ow is at the burner before closing the door Ensure adequate ventilation For gas and electrical locations see dimensions section All gas connections must be contained with...

Страница 24: ...tal vent Sides and bottom 1 25mm Top 2 51mm Vertical Vent All sides 1 25mm At a distance of 2 51mm from the wall access to the blower switch on off switch or the blower power cord may not be practical...

Страница 25: ...he door meets the door retainer before closing the latches Follow the above steps in reverse order to reinstall the cast front Ensure that the tabs on the underside of the front t behind the front leg...

Страница 26: ...cradle the centre of the log F Place the hole in the underside of log 3 onto the locating screw on the right side of the burner The bottom branch of log 3 sits in front of and against the right end o...

Страница 27: ...CHES F Open the switch housing by removing the top screw G Install the thermal switch bracket as illustrated using 2 of the screws supplied Connect the agged leads to the terminals of the thermal swit...

Страница 28: ...he battery holder to the wire harness before using the appliance Place near the IPI board If the back up is used it must be connected to this 6 volt battery pack supplied Do not connect to a 9 volt ba...

Страница 29: ...lease If pilot does not continue to burn repeat steps E through I J With pilot lit turn gas knob counter clockwise to the ON position K If equipped with the ame adjustment valve push and turn the knob...

Страница 30: ...ipped I Turn on the remote wall switch to the appliance J If the appliance will not operate follow instructions TO TURN OFF GAS and call your service technician or gas supplier A Set thermostat to low...

Страница 31: ...off A timer will then begin the countdown for approximately seven days before shutting off the pilot if the appliance is not used This countdown will reset anytime the appliance main burner is used Th...

Страница 32: ...rub pad such as Scotch Brite can be used to remove the paint from the pilot hood electrode and ame sensor INSERT PILOT ASSEMBLY Maximum inlet pressure not to exceed 13 Pressure Natural Gas inches Natu...

Страница 33: ...cleaned logs rocks or glass Failure to properly position the media may cause carboning which can be distributed in the surrounding living area inside the rebox and on exterior surfaces sur rounding ve...

Страница 34: ...nsure they open freely and close sealed Check the gas control valve pilot and Hi Lo knobs move freely if equipped Replace if any stiffness in movement is experienced Check for gas leaks on all gas con...

Страница 35: ...ct you local authorized dealer distributor for complete cleaning instructions Razor blades steel wool or other metallic objects must not be used on both surfaces of the glass Doing so can remove a thi...

Страница 36: ...ts can be ordered through your Authorized dealer distributor For warranty replacement parts a photocopy of the original invoice will be required to honour the claim When ordering replacement parts alw...

Страница 37: ...arness pilot light assembly MV W660 0009 ON OFF switch W690 0002 Thermodisc W357 0001 Push button ignitor MV W090 0115 Porcelain Panel W080 1987 Magnet bracket EI 10 Log set 8 9 10 11 12 13 14 13 15 W...

Страница 38: ...ber 1 W080 0751 Pilot bracket 2 3 W010 0798 Pilot assembly NG 4 W010 0800 4 W680 0005 Thermocouple 5 6 7 Ref No Part Number 8 W035 0141 Burner base 9 W080 0722 Top valve bracket X2 9 W432 0063 Manifol...

Страница 39: ...Pilot assembly NG 3 W010 0800 4 W680 0005 Thermocouple 5 6 7 Ref No Part Number 10 W035 0513 Burner base 10 W080 1725 Top valve bracket X2 11 W456 0045 Burner ori ce 45 NG 12 W456 0055 Burner ori ce...

Страница 40: ...ceiling plate 2 W025 0001 Decorative brass brand 3 RP4 4 Restrictor plate 4 F50 Remote control 5 GS 65KT Blower kit 6 Ref No Part Number W 065 0024 Hex head bolt GDSLL KT W 570 013 Hex head screw GDSL...

Страница 41: ...OCKWISE FIRMLY TO RESEAL DO NOT OVER TORQUE Leak test with a soap and water solution Air shutter improperly adjusted Return air shutter to speci ed opening see venturi adjustment section Carbon is bei...

Страница 42: ...shorting faulty Loosen and tighten thermocouple Clean thermocouple and valve connection Replace thermocouple Replace valve Faulty valve Replace Pilot burning no gas to main burner gas knob is on HI w...

Страница 43: ...VER TORQUE Leak test with a soap and water solution Air shutter improperly adjusted Return air shutter to speci ed opening see venturi adjustments section in the installation manual Carbon is being de...

Страница 44: ...d Receiver if equipped Reset program hold reset button on receiver and wait for 2 beeps Release after second beep Press small ame button on remote within 20 seconds you will hear an additional beep th...

Страница 45: ...Choose one of the 3 methods below to reset the system 1 To reset ignition box when locked out Turn off power supply and remove batteries if used from the back up battery pack 2 To reset the DFC Board...

Страница 46: ...s such as rooftops buildings nearby trees hills mountains inadequate vents or ventilation excessive venting con gurations insuf cient makeup air or negative air pressures which may or may not be cause...

Страница 47: ...EN W415 2884 A 09 21 20 47 16 0 notes...

Страница 48: ...Produced and distributed by 24 Napoleon Road Barrie Ontario Canada L4M 0G8 Tel timberwolffireplaces com...

Страница 49: ...ce d entretien ou le fournisseur Cet appareil peut tre install dans une maison pr fabriqu e mobile d j install e demeure si les r glements locaux le permettent Cet appareil doit tre utilis uniquement...

Страница 50: ...x br lures accidentelles Une barri re de protection est recommand e si des individus risque se trouvent dans la maison A n de restreindre l acc s l appareil installez une barri re de protection ajusta...

Страница 51: ...leur s propre peut entra ner la formation de suies et dommages la propri t Comme dans le cas de tout appareil combustion il est recommand de faire inspecter et entretenir votre appareil r guli rement...

Страница 52: ...l 66 3 4 installation de la terminaison horizontale 67 3 5 terminaison verticale travers une chemin e 68 3 6 installation de la terminaison verticale 69 3 7 branchement du gaz 70 3 8 interrupteur mura...

Страница 53: ...re install dans une maison mobile install e en permanence et aliment e au gaz naturel Cet appareil ne doit fonctionner qu avec le gaz sp ci sur la plaque d homologation Cet appareil ne peut tre conver...

Страница 54: ...o le souf erie est quip d un cordon d alimentation il doit tre connect une r ceptacle correctement mise la terre La che de mise la terre ne doit pas tre retir du cordon d alimentation Ce qui suit ne...

Страница 55: ...ion pour des extensions plus grandes les longueurs d vacuation minimaux et maximum The appliance must be vented using the appropriate Napoleon vent kits See installation manual for venting speci catio...

Страница 56: ...W415 2884 A 09 21 20 56 FR information g n rales 25 3 8 645mm SAFETY SCREEN 18 1 2 470mm 24 610mm 19 1 4 4 102mm 7 178mm 489mm 9 5 8 245mm L CRAN DE PROTECTION 1 4 dimensions...

Страница 57: ...d vents approuv s l exception du raccordement du conduit d vacuation la buse du foyer qui doit tre scell avec le scellant noir haute temp rature Mill Pac Le scellant haute temp rature doit tre comman...

Страница 58: ...ed ou 0mm par m tre mais pour une performance optimale nous recommandons que toutes les courses horizontales devraient avoir un l vation minimum de 1 4 par pied ou 21mm par m tre lors d utilisation d...

Страница 59: ...pieds 2 4m pour un po le Lorsque l vent est install en coin la longueur maximale du conduit d vacuation est de 24 610mm de course horizontale en plus de la d viation de 45 Dans ce cas une pente de z...

Страница 60: ...des murs adjacents incluant les maisons voisines P 8 2 4m 8 2 4m Le toit doit tre incombustible et sans ouvertures Q 3 0 9m 3 0 9m Voir le tableau pour les dimensions d un mur plus large R 6 1 8m 6 1...

Страница 61: ...respectivement ou 135 lorsque combin es Pour la 45 sortie seulement 90 90 45 V1 H1 H2 HT VT 0 2 5 0 8 5 1 5 7 5 2 3 10 3 1 12 5 3 8 15 4 6 10 3 1 20 6 1 30 9 1 17 5 5 3 20 6 1 39 11 9 Con guration d v...

Страница 62: ...5 8m Formula 1 HT 4 2PI 1 3m VT 4 2PI 1 3m VT 4 2PI 1 3m x 5 5PI 1 7m 23 1PI 7m 13 6PI 4 2m 23 1PI 7M Formula 2 HT VT 24 75PI 7 5m 19 1PI 5 8m 24 75PI 7 5m Puisque les deux formules sont respect es c...

Страница 63: ...aleurs acceptables pour HT et VT Lorsque la con guration de l vacuation exige plus qu un coude de 45 et un coude de 90 les formules suivantes s appliquent Formule 1 HT VT Formule 2 HT VT 40 pieds 12 2...

Страница 64: ...70 135 5 4 PI 1 6m HT HR HO 8 PI 2 4m 5 4 PI 1 6m 13 4 PI 4 1m HT VT 13 4 PI 4 1m 2 5 PI 0 8m 15 9 PI 4 8m Formule 1 HT 3VT 3VT 3PI 0 9m x 2 5PI 0 8m 7 5PI 2 3m 13 4PI 4 1m 7 5PI 2 3m Puisque cette fo...

Страница 65: ...ceur coupe feu Installez les crans muraux et les espaceurs coupe feu tel que sp ci Si vous ne gardez pas l isolant ou tout autre mat riau l cart du conduit d vent un risque d incendie pourrait s ensui...

Страница 66: ...onduit d vacuation et l espaceur coupe feu Calfeutrage Protecteur du conduit d vacuation Protecteur du conduit d vacuation Collet de conduit d vacuation Espaceur coupe feu face inf rieure des solves C...

Страница 67: ...nt n cessaire aux mat riaux combustibles En soutenant la terminaison les inscriptions tant l endroit et lisibles xez la au mur ext rieur et rendez la tanche en la scellant avec du calfeutrage non four...

Страница 68: ...ccord au conduit exible de prise d air et le collet d vacuation de la terminaison au conduit exible d vacuation Les adaptateurs colin aire coaxial Simpson Duravent et Selkirk sont approuv s pour cet a...

Страница 69: ...connecteur de terminaison en laissant un minimum de 3 4 19 1mm de connecteur de terminaison visible au dessus du haut du solin Glissez le solin sous les c t s et le bord sup rieur des bardeaux Assurez...

Страница 70: ...13mm Sans raccord exible l appareil est con u pour recevoir une conduite de gaz de 3 8 9 5mm L appareil est muni d une soupape d arr t manuelle pour fermer l alimentation en gaz Branchez le gaz en co...

Страница 71: ...NS D EVENTS VERTICALES Un d gagement minimal aux mat riaux combustibles de 1 25mm est requis sur toutes les courses verticales Utilisez l espaceur coupe feu W500 0097 non fourni 121 9cm NOTE Si l appa...

Страница 72: ...que les pattes situ es sous la fa ade en fonte soient plac es derri re les pattes avant du po le Note Il n est pas n cessaire de retirer la fa ade en fonte pour retirer la porte A Soulevez et retirez...

Страница 73: ...fa on pouser la forme de la b che F Placez le trou sous la b che 3 sur la vis de positionnement du c t droit du br leur La branche inf rieure de la b che 3 est plac e devant et con tre l extr mit dro...

Страница 74: ...G G H I INTERRUPTEURS F Ouvrez le bo tier d interrupteur en retirant la vis du haut G Installez le support du thermodisque tel qu illustr l aide de deux des vis fournies Branchez les ls avec raccords...

Страница 75: ...de contr le Si le sauvegarde est utiliser il doit tre connect cet pile de 6V fourni Ne branchez le pas un pile de 9V note Ne raccordez pas l interrupteur mural ou la soupape de gaz l alimentation lec...

Страница 76: ...le bouton poussoir d ignition Gardez le bouton de contr le du gaz enfonc pendant une minute puis rel chez le Si la veilleuse ne reste pas allum e r p tez les tapes E I J Lorsque la veilleuse est allu...

Страница 77: ...e pas suivre les instructions de couper l alimentation de gaz et puis appelez votre technicien de service ou fournisseur de gaz A R gler le thermostat la r glage le plus bas si quip B Tournez l interr...

Страница 78: ...e d compte se r initialisera chaque fois que le br leur principal de l appareil sera allum Par cons quent si l appareil est utilis r guli rement sur une base journali re la veilleuse restera allum e C...

Страница 79: ...serrez pas trop fort V ri ez pour des fuites en appliquant une solution d eau savonneuse Avant d effectuer le r glage de la veilleuse assurez vous que l assemblage de la veilleuse n a pas t peint S i...

Страница 80: ...VOLET D AIR VENTURI INJECTEUR Il est important que l injecteur soit correctement ins r dans le venturi note Il est important d effectuer p riodiquement une inspection visuelle de la amme de la veille...

Страница 81: ...eur 5 Si votre appareil est fourni avec une cran de protection le nettoyage peut tre n cessaire en raison d un exc s de poussi re peluches des tapis animaux etc utilisez un l attachement du brosse sur...

Страница 82: ...pr nettoyage Enlevez aussi tout d p t se trouvant sur l assemblage de la veilleuse et aussi s il y a lieu sur la thermopile le thermocouple le capteur de amme et l allumeur Inspectez tous les joints d...

Страница 83: ...qu il le faudra sinon la vitre risque de rester marqu e en permanance Ne touchez pas la surface int rieure ou ext rieur de la vitre avec des lames de rasoir de la laine d acier ou d autres objets m t...

Страница 84: ...les pi ces peuvent tre command es chez votre d taillant autoris Pour un remplacement de pi ce sous garantie une photocopie de la facture originale sera requise a n de pouvoir honorer la demande Lorsqu...

Страница 85: ...5 Aimantes du support MV Pour les pi ces de rechange voir la section assemblage de la soupape 8 8 GL 651 GL 651 SER Ensemble de b ches 10 9 Barri re de protection 1 2 3 4 5 6 7 8 9 10 11 12 14 13 15 1...

Страница 86: ...veilleuse GN 4 W010 0799 Assemblage de veilleuse P 5 W680 0005 Thermocouple 6 W010 3048 Assemblage du br leur 7 8 R f No de pi ce Description 9 W035 0141 Base du br leur 10 W080 0722 Support de la so...

Страница 87: ...0751 Support de veilleuse 2 3 W010 2763 Assemblage de veilleuse GN 3 W010 2808 Assemblage de veilleuse P 4 W680 0005 Thermocouple 5 W010 3048 Assemblage du br leur 6 7 R f No de pi ce Description 10 W...

Страница 88: ...laiton 3 RP4 4 Plaque de restriction 4 F50 T l commande 5 GS 654KT Souf erie 6 7 R f No de pi ce Description W065 0020 W160 0041 9 W570 0026 10 W530 0014 R gulateur P W175 0234 11 W456 0055 Injecteur...

Страница 89: ...NE SERREZ PAS TROP FORT V ri ez pour des fuites en appliquant une solution d eau savonneuse Le volet d air est mal r gl Voir la section r glage du venturi pour le r glage de l ouverture du volet d ai...

Страница 90: ...ettoyez le thermocouple et la connexion la borne de la soupape Remplacez le thermocouple Remplacez la soupape La soupape est d fecteuse Remplacez la soupape La veilleuse br le pas de gaz au br leur pr...

Страница 91: ...t d air est r gl incorrectement Voir la section r glage du venturi pour le r glage de l ouverture du volet d air dans le manual d installation Du carbone se d pose sur la vitre les b ches les roches l...

Страница 92: ...mentation de la veilleuse Le module n est pas mis la terre Assurez le bon polarit du thermocouple si fourni V ri ez si les assemblages de le veilleuse et de la soupape sont bien mis la terre R cepteur...

Страница 93: ...rie fonctionnent si quip La bo te d allumage a t verrouill e Choisissez l une des trois m thodes suivantes pour r initialiser le syst me 1 Pour r initialiser la bo te d allumage lorsqu elle a t verro...

Страница 94: ...s ventilateurs d vacuation les fournaises les s cheuses de linge etc Tous dommages caus s a l appareil la chambre de combustion l changeur de chaleur aux garnitures de laiton ou autres composants par...

Страница 95: ...W415 2884 A 09 21 20 95 FR 16 0 notes...

Страница 96: ...ProduJUT FU EJTUSJCV T QBS 24 Napoleon Road Barrie Ontario Canada L4M 0G8 T l timberwolffireplaces com...

Отзывы: