general information

The blower power cord must be connected into a properly grounded receptacle. The grounding prong must not 
be removed from the cord plug.

THIS GAS APPLIANCE MUST BE INSTALLED AND SERVICED BY A QUALIFIED INSTALLER

 to conform with local 

codes. Installation practices vary from region to region and it is important to know the specifi cs that apply to your area, for 
example in the state of Massachusetts: 
• 

This product must be installed by a licensed plumber or gas fi tter when installed within the commonwealth of 
Massachusetts.

• 

The appliance damper must be removed or welded in the open position prior to installation of an appliance insert or gas 
log.

• 

The appliance off valve must be a “T” handle gas cock.

• 

The fl exible connector must not be longer than 36 inches (0.9m).

• 

A carbon monoxide detector is required in all rooms containing gas fi red appliances.

• 

The appliance is not approved for installation in a bedroom or bathroom unless the unit is a direct vent sealed 
combustion product.

 The installation must conform with local codes or, in absence of local 
codes, the National Gas and Propane Installation Code CSA B149.1 
in Canada, or the National Fuel Gas Code, ANSI Z223.1 / NFPA 54 
in the United States. Suitable for mobile home installation if installed 
in accordance with the current standard CAN/CSA Z240MH Series, 
for gas equipped mobile homes, in Canada or ANSI Z223.1 and 
NFPA 54 in the United States.

The appliance and its individual shutoff valve must be disconnected 
from the gas supply piping system during any pressure testing 
of that system at test pressures in excess of 1/2 psig (35 mb). 
The appliance must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any 
pressure testing of the gas supply piping  system at test pressures equal to or less than 1/2 psig (35 mb). When installed 
with a blower or fan, the junction box must be electrically connected and grounded in accordance with local codes. In the 
absence of local codes, use the current CSA C22.1 Canadian Electrical Code in Canada or the ANSI / NFPA 70 National 
Electric Code in the United States. In the case where the blower is equipped with a power cord, it must be connected into a 
properly grounded receptacle. The grounding prong must not be removed from the cord plug.

The following does not apply to inserts; as long as the required clearance to combustibles is maintained, the most desirable 
and benefi cial location for an appliance is in the center of a building, thereby allowing the most effi cient use of the heat 
created. The location of windows, doors and, the traffi c fl ow in the room where the appliance is to be located should be 
considered. If possible, you should choose a location where the vent will pass through the house without cutting a fl oor or 
roof joist. If the appliance is installed directly on carpeting, vinyl tile or other combustible material other than wood fl ooring, the 
appliance shall be installed on a metal or wood panel extending the full width and depth, unless otherwise tested.

We suggest that our gas 
hearth products be installed 
and serviced by professionals 
who are certified in the U.S. 
by the National Fireplace 
Institute

® (NFI) as NFI Gas 

Specialists

www.nficertified.org

• 

Always light the pilot - whether for the fi rst time or if the gas supply has run out - with the glass door opened or 
removed.

• 

Provide adequate clearance for servicing and operating the appliance.

• 

Provide adequate ventilation.

• 

Never obstruct the front opening of the appliance.

• 

Objects placed in front of the appliance must be kept a minimum of 48" (121.9cm) from the front face of the 
appliance.

• 

Surfaces around and especially above the appliance can become hot. Avoid contact when the appliance is 
operating.

• 

Fire risk. Explosion hazard.

• 

High pressure will damage valve. Disconnect gas supply piping before pressure testing gas line at test pressures 
above 1/2psig. Close the manual shut-off valve before pressure testing gas line at test pressures equal to or 
less than 1/2psig (35mb).

• 

Use only Wolf Steel-approved optional accessories and replacement parts with this appliance. Using non-listed 
accessories (blowers, doors, louvres, trims, gas components, venting components, etc.) could result in a safety 
hazard and will void the warranty and certifi cation.

!

WARNING

1.2 general 

instructions

Содержание TDS20 Series

Страница 1: ...any electrical switch do not use any phone in your building Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach your gas supplier ca...

Страница 2: ...t burns A physical barrier is recommended if there are at risk individuals in the house To restrict access to an appliance or stove install an adjustable safety gate to keep toddlers young children an...

Страница 3: ...anemia those under the in uence of alcohol those at high altitudes are more affected by carbon monoxide than others Failure to keep the primary air opening s of the burner s clean may result in sooti...

Страница 4: ...ustibles 24 Batteries must be disposed of according to the local laws and regulations Some batteries may be recycled and may be accepted for disposal at your local recycling center Check with your mun...

Страница 5: ...to be located should be considered If possible you should choose a location where the vent will pass through the house without cutting a oor or roof joist This appliance is approved for closet or rec...

Страница 6: ...trical Code in Canada or the ANSI NFPA 70 National Electric Code in the United States In the case where the blower is equipped with a power cord it must be connected into a properly grounded receptacl...

Страница 7: ...on pour les sp ci cations d vacuation Il est n cessaire de bien r installer et resceller l vacuation apr s avoir executer l entretien du syst me de prise d air Serial Number N de S rie W385 XXXX REFER...

Страница 8: ...W415 2884 A 09 21 20 EN 8 general information 1 5 dimensions 25 3 8 645mm SAFETY SCREEN 18 1 2 470mm 24 610mm 19 1 4 4 102mm 7 178mm 489mm 9 5 8 245mm...

Страница 9: ...mbined Different venting manufacturer components must not be combined These vent kits allow for either horizontal or vertical venting of the appliance The maximum allowable horizontal run is 20 feet 6...

Страница 10: ...minate directly above a sidewalk or paved driveway which is located between two single family dwellings and serves both dwellings Local codes or regulations may require different clearances Do not all...

Страница 11: ...ble See illustrations below It is recommended to maintain a 6 152mm rise 24 61cm maximum Use the periscope kit to locate the air termination above grade The periscope must be installed so that when na...

Страница 12: ...hang N 16 40 6cm 16 40 6cm Clearance above the roof O 2 0 6m 2 0 6m Clearance from an adjacent wall including neighbouring buildings P 8 2 4m 8 2 4m Roof must be non combustible without openings Q 3 0...

Страница 13: ...and is shown in the formula as 45 and 90 respectively or 135 when combined for 45 exit only For the following symbols used in the venting calculations and examples are greater than equal to or greater...

Страница 14: ...gurations requiring more than two 90 elbows the following formulas apply Formula 1 HT VT Formula 2 HT VT 40 feet 12 2m Example V1 8 FT 2 4m VT V1 8 FT 2 4m H1 2 5 FT 0 8m H2 2 FT 0 6m HR H1 H2 2 5FT...

Страница 15: ...7 5m Example V1 4 FT 1 2m V2 1 5 FT 0 5m VT V1 V2 4FT 1 2m 1 5FT 0 5m 5 5 FT 1 7m H1 2 FT 0 6m H2 1 FT 0 3m H3 1 FT 0 3m H4 1 5 FT 0 5m HR H1 H2 H3 H4 2FT 0 6m 1FT 0 3m 1FT 0 3m 1 5FT 0 5m 5 5 FT 1 7...

Страница 16: ...2 2m Example V1 5 FT 1 5m V2 10 FT 3 1m VT V1 V2 5 FT 1 5m 10 FT 3 1m 15 FT 4 6m H1 3 FT 0 9m H2 2 5 FT 0 8m HR H1 H2 3FT 0 9m 2 5FT 0 8m 5 5 FT 1 7m HO 03 one 45 three 90 elbows 135 03 45 270 135 5 4...

Страница 17: ...35 5 4 FT 1 6m HT HR HO 8FT 2 4m 5 4FT 1 6m 13 4FT 4 1m HT VT 13 4FT 4 1m 2 5FT 0 8m 15 9FT 4 8m Formula 1 HT 3VT 3VT 3FT 0 9m x 2 5FT 0 8m 7 5FT 2 3m 13 4 FT 4 1m 7 5 FT 2 3m Since this formula is no...

Страница 18: ...t pipe may cause re For gas stoves only If the appliance is installed directly on carpeting vinyl tile or other combustible material other than wood ooring the appliance shall be installed on a metal...

Страница 19: ...clearance to combustibles Once the vent pipe is installed in its nal position apply red RTV silicone W573 0002 not supplied between the pipe and the restop assembly C In the attic slide the vent pipe...

Страница 20: ...e weather tight by sealing with caulking not supplied D If more vent pipe needs to be used to reach the replace couple them together as illustrated The vent system must be supported approximately ever...

Страница 21: ...intake ex liner and the exhaust collar must be connected to the exhaust exible liner Both Simpson Duravent and Selkirk co linear to co axial adaptors have been approved on this appliance Follow vent...

Страница 22: ...g over the air terminal connector leaving a min 3 4 19mm of the air terminal connector showing above the top of the ashing Slide the ashing underneath the sides and upper edge of the shingles Ensure t...

Страница 23: ...Ensure that a continuous gas ow is at the burner before closing the door Ensure adequate ventilation For gas and electrical locations see dimensions section All gas connections must be contained with...

Страница 24: ...tal vent Sides and bottom 1 25mm Top 2 51mm Vertical Vent All sides 1 25mm At a distance of 2 51mm from the wall access to the blower switch on off switch or the blower power cord may not be practical...

Страница 25: ...he door meets the door retainer before closing the latches Follow the above steps in reverse order to reinstall the cast front Ensure that the tabs on the underside of the front t behind the front leg...

Страница 26: ...cradle the centre of the log F Place the hole in the underside of log 3 onto the locating screw on the right side of the burner The bottom branch of log 3 sits in front of and against the right end o...

Страница 27: ...CHES F Open the switch housing by removing the top screw G Install the thermal switch bracket as illustrated using 2 of the screws supplied Connect the agged leads to the terminals of the thermal swit...

Страница 28: ...he battery holder to the wire harness before using the appliance Place near the IPI board If the back up is used it must be connected to this 6 volt battery pack supplied Do not connect to a 9 volt ba...

Страница 29: ...lease If pilot does not continue to burn repeat steps E through I J With pilot lit turn gas knob counter clockwise to the ON position K If equipped with the ame adjustment valve push and turn the knob...

Страница 30: ...ipped I Turn on the remote wall switch to the appliance J If the appliance will not operate follow instructions TO TURN OFF GAS and call your service technician or gas supplier A Set thermostat to low...

Страница 31: ...off A timer will then begin the countdown for approximately seven days before shutting off the pilot if the appliance is not used This countdown will reset anytime the appliance main burner is used Th...

Страница 32: ...rub pad such as Scotch Brite can be used to remove the paint from the pilot hood electrode and ame sensor INSERT PILOT ASSEMBLY Maximum inlet pressure not to exceed 13 Pressure Natural Gas inches Natu...

Страница 33: ...cleaned logs rocks or glass Failure to properly position the media may cause carboning which can be distributed in the surrounding living area inside the rebox and on exterior surfaces sur rounding ve...

Страница 34: ...nsure they open freely and close sealed Check the gas control valve pilot and Hi Lo knobs move freely if equipped Replace if any stiffness in movement is experienced Check for gas leaks on all gas con...

Страница 35: ...ct you local authorized dealer distributor for complete cleaning instructions Razor blades steel wool or other metallic objects must not be used on both surfaces of the glass Doing so can remove a thi...

Страница 36: ...ts can be ordered through your Authorized dealer distributor For warranty replacement parts a photocopy of the original invoice will be required to honour the claim When ordering replacement parts alw...

Страница 37: ...arness pilot light assembly MV W660 0009 ON OFF switch W690 0002 Thermodisc W357 0001 Push button ignitor MV W090 0115 Porcelain Panel W080 1987 Magnet bracket EI 10 Log set 8 9 10 11 12 13 14 13 15 W...

Страница 38: ...ber 1 W080 0751 Pilot bracket 2 3 W010 0798 Pilot assembly NG 4 W010 0800 4 W680 0005 Thermocouple 5 6 7 Ref No Part Number 8 W035 0141 Burner base 9 W080 0722 Top valve bracket X2 9 W432 0063 Manifol...

Страница 39: ...Pilot assembly NG 3 W010 0800 4 W680 0005 Thermocouple 5 6 7 Ref No Part Number 10 W035 0513 Burner base 10 W080 1725 Top valve bracket X2 11 W456 0045 Burner ori ce 45 NG 12 W456 0055 Burner ori ce...

Страница 40: ...ceiling plate 2 W025 0001 Decorative brass brand 3 RP4 4 Restrictor plate 4 F50 Remote control 5 GS 65KT Blower kit 6 Ref No Part Number W 065 0024 Hex head bolt GDSLL KT W 570 013 Hex head screw GDSL...

Страница 41: ...OCKWISE FIRMLY TO RESEAL DO NOT OVER TORQUE Leak test with a soap and water solution Air shutter improperly adjusted Return air shutter to speci ed opening see venturi adjustment section Carbon is bei...

Страница 42: ...shorting faulty Loosen and tighten thermocouple Clean thermocouple and valve connection Replace thermocouple Replace valve Faulty valve Replace Pilot burning no gas to main burner gas knob is on HI w...

Страница 43: ...VER TORQUE Leak test with a soap and water solution Air shutter improperly adjusted Return air shutter to speci ed opening see venturi adjustments section in the installation manual Carbon is being de...

Страница 44: ...d Receiver if equipped Reset program hold reset button on receiver and wait for 2 beeps Release after second beep Press small ame button on remote within 20 seconds you will hear an additional beep th...

Страница 45: ...Choose one of the 3 methods below to reset the system 1 To reset ignition box when locked out Turn off power supply and remove batteries if used from the back up battery pack 2 To reset the DFC Board...

Страница 46: ...s such as rooftops buildings nearby trees hills mountains inadequate vents or ventilation excessive venting con gurations insuf cient makeup air or negative air pressures which may or may not be cause...

Страница 47: ...EN W415 2884 A 09 21 20 47 16 0 notes...

Страница 48: ...Produced and distributed by 24 Napoleon Road Barrie Ontario Canada L4M 0G8 Tel timberwolffireplaces com...

Страница 49: ...ce d entretien ou le fournisseur Cet appareil peut tre install dans une maison pr fabriqu e mobile d j install e demeure si les r glements locaux le permettent Cet appareil doit tre utilis uniquement...

Страница 50: ...x br lures accidentelles Une barri re de protection est recommand e si des individus risque se trouvent dans la maison A n de restreindre l acc s l appareil installez une barri re de protection ajusta...

Страница 51: ...leur s propre peut entra ner la formation de suies et dommages la propri t Comme dans le cas de tout appareil combustion il est recommand de faire inspecter et entretenir votre appareil r guli rement...

Страница 52: ...l 66 3 4 installation de la terminaison horizontale 67 3 5 terminaison verticale travers une chemin e 68 3 6 installation de la terminaison verticale 69 3 7 branchement du gaz 70 3 8 interrupteur mura...

Страница 53: ...re install dans une maison mobile install e en permanence et aliment e au gaz naturel Cet appareil ne doit fonctionner qu avec le gaz sp ci sur la plaque d homologation Cet appareil ne peut tre conver...

Страница 54: ...o le souf erie est quip d un cordon d alimentation il doit tre connect une r ceptacle correctement mise la terre La che de mise la terre ne doit pas tre retir du cordon d alimentation Ce qui suit ne...

Страница 55: ...ion pour des extensions plus grandes les longueurs d vacuation minimaux et maximum The appliance must be vented using the appropriate Napoleon vent kits See installation manual for venting speci catio...

Страница 56: ...W415 2884 A 09 21 20 56 FR information g n rales 25 3 8 645mm SAFETY SCREEN 18 1 2 470mm 24 610mm 19 1 4 4 102mm 7 178mm 489mm 9 5 8 245mm L CRAN DE PROTECTION 1 4 dimensions...

Страница 57: ...d vents approuv s l exception du raccordement du conduit d vacuation la buse du foyer qui doit tre scell avec le scellant noir haute temp rature Mill Pac Le scellant haute temp rature doit tre comman...

Страница 58: ...ed ou 0mm par m tre mais pour une performance optimale nous recommandons que toutes les courses horizontales devraient avoir un l vation minimum de 1 4 par pied ou 21mm par m tre lors d utilisation d...

Страница 59: ...pieds 2 4m pour un po le Lorsque l vent est install en coin la longueur maximale du conduit d vacuation est de 24 610mm de course horizontale en plus de la d viation de 45 Dans ce cas une pente de z...

Страница 60: ...des murs adjacents incluant les maisons voisines P 8 2 4m 8 2 4m Le toit doit tre incombustible et sans ouvertures Q 3 0 9m 3 0 9m Voir le tableau pour les dimensions d un mur plus large R 6 1 8m 6 1...

Страница 61: ...respectivement ou 135 lorsque combin es Pour la 45 sortie seulement 90 90 45 V1 H1 H2 HT VT 0 2 5 0 8 5 1 5 7 5 2 3 10 3 1 12 5 3 8 15 4 6 10 3 1 20 6 1 30 9 1 17 5 5 3 20 6 1 39 11 9 Con guration d v...

Страница 62: ...5 8m Formula 1 HT 4 2PI 1 3m VT 4 2PI 1 3m VT 4 2PI 1 3m x 5 5PI 1 7m 23 1PI 7m 13 6PI 4 2m 23 1PI 7M Formula 2 HT VT 24 75PI 7 5m 19 1PI 5 8m 24 75PI 7 5m Puisque les deux formules sont respect es c...

Страница 63: ...aleurs acceptables pour HT et VT Lorsque la con guration de l vacuation exige plus qu un coude de 45 et un coude de 90 les formules suivantes s appliquent Formule 1 HT VT Formule 2 HT VT 40 pieds 12 2...

Страница 64: ...70 135 5 4 PI 1 6m HT HR HO 8 PI 2 4m 5 4 PI 1 6m 13 4 PI 4 1m HT VT 13 4 PI 4 1m 2 5 PI 0 8m 15 9 PI 4 8m Formule 1 HT 3VT 3VT 3PI 0 9m x 2 5PI 0 8m 7 5PI 2 3m 13 4PI 4 1m 7 5PI 2 3m Puisque cette fo...

Страница 65: ...ceur coupe feu Installez les crans muraux et les espaceurs coupe feu tel que sp ci Si vous ne gardez pas l isolant ou tout autre mat riau l cart du conduit d vent un risque d incendie pourrait s ensui...

Страница 66: ...onduit d vacuation et l espaceur coupe feu Calfeutrage Protecteur du conduit d vacuation Protecteur du conduit d vacuation Collet de conduit d vacuation Espaceur coupe feu face inf rieure des solves C...

Страница 67: ...nt n cessaire aux mat riaux combustibles En soutenant la terminaison les inscriptions tant l endroit et lisibles xez la au mur ext rieur et rendez la tanche en la scellant avec du calfeutrage non four...

Страница 68: ...ccord au conduit exible de prise d air et le collet d vacuation de la terminaison au conduit exible d vacuation Les adaptateurs colin aire coaxial Simpson Duravent et Selkirk sont approuv s pour cet a...

Страница 69: ...connecteur de terminaison en laissant un minimum de 3 4 19 1mm de connecteur de terminaison visible au dessus du haut du solin Glissez le solin sous les c t s et le bord sup rieur des bardeaux Assurez...

Страница 70: ...13mm Sans raccord exible l appareil est con u pour recevoir une conduite de gaz de 3 8 9 5mm L appareil est muni d une soupape d arr t manuelle pour fermer l alimentation en gaz Branchez le gaz en co...

Страница 71: ...NS D EVENTS VERTICALES Un d gagement minimal aux mat riaux combustibles de 1 25mm est requis sur toutes les courses verticales Utilisez l espaceur coupe feu W500 0097 non fourni 121 9cm NOTE Si l appa...

Страница 72: ...que les pattes situ es sous la fa ade en fonte soient plac es derri re les pattes avant du po le Note Il n est pas n cessaire de retirer la fa ade en fonte pour retirer la porte A Soulevez et retirez...

Страница 73: ...fa on pouser la forme de la b che F Placez le trou sous la b che 3 sur la vis de positionnement du c t droit du br leur La branche inf rieure de la b che 3 est plac e devant et con tre l extr mit dro...

Страница 74: ...G G H I INTERRUPTEURS F Ouvrez le bo tier d interrupteur en retirant la vis du haut G Installez le support du thermodisque tel qu illustr l aide de deux des vis fournies Branchez les ls avec raccords...

Страница 75: ...de contr le Si le sauvegarde est utiliser il doit tre connect cet pile de 6V fourni Ne branchez le pas un pile de 9V note Ne raccordez pas l interrupteur mural ou la soupape de gaz l alimentation lec...

Страница 76: ...le bouton poussoir d ignition Gardez le bouton de contr le du gaz enfonc pendant une minute puis rel chez le Si la veilleuse ne reste pas allum e r p tez les tapes E I J Lorsque la veilleuse est allu...

Страница 77: ...e pas suivre les instructions de couper l alimentation de gaz et puis appelez votre technicien de service ou fournisseur de gaz A R gler le thermostat la r glage le plus bas si quip B Tournez l interr...

Страница 78: ...e d compte se r initialisera chaque fois que le br leur principal de l appareil sera allum Par cons quent si l appareil est utilis r guli rement sur une base journali re la veilleuse restera allum e C...

Страница 79: ...serrez pas trop fort V ri ez pour des fuites en appliquant une solution d eau savonneuse Avant d effectuer le r glage de la veilleuse assurez vous que l assemblage de la veilleuse n a pas t peint S i...

Страница 80: ...VOLET D AIR VENTURI INJECTEUR Il est important que l injecteur soit correctement ins r dans le venturi note Il est important d effectuer p riodiquement une inspection visuelle de la amme de la veille...

Страница 81: ...eur 5 Si votre appareil est fourni avec une cran de protection le nettoyage peut tre n cessaire en raison d un exc s de poussi re peluches des tapis animaux etc utilisez un l attachement du brosse sur...

Страница 82: ...pr nettoyage Enlevez aussi tout d p t se trouvant sur l assemblage de la veilleuse et aussi s il y a lieu sur la thermopile le thermocouple le capteur de amme et l allumeur Inspectez tous les joints d...

Страница 83: ...qu il le faudra sinon la vitre risque de rester marqu e en permanance Ne touchez pas la surface int rieure ou ext rieur de la vitre avec des lames de rasoir de la laine d acier ou d autres objets m t...

Страница 84: ...les pi ces peuvent tre command es chez votre d taillant autoris Pour un remplacement de pi ce sous garantie une photocopie de la facture originale sera requise a n de pouvoir honorer la demande Lorsqu...

Страница 85: ...5 Aimantes du support MV Pour les pi ces de rechange voir la section assemblage de la soupape 8 8 GL 651 GL 651 SER Ensemble de b ches 10 9 Barri re de protection 1 2 3 4 5 6 7 8 9 10 11 12 14 13 15 1...

Страница 86: ...veilleuse GN 4 W010 0799 Assemblage de veilleuse P 5 W680 0005 Thermocouple 6 W010 3048 Assemblage du br leur 7 8 R f No de pi ce Description 9 W035 0141 Base du br leur 10 W080 0722 Support de la so...

Страница 87: ...0751 Support de veilleuse 2 3 W010 2763 Assemblage de veilleuse GN 3 W010 2808 Assemblage de veilleuse P 4 W680 0005 Thermocouple 5 W010 3048 Assemblage du br leur 6 7 R f No de pi ce Description 10 W...

Страница 88: ...laiton 3 RP4 4 Plaque de restriction 4 F50 T l commande 5 GS 654KT Souf erie 6 7 R f No de pi ce Description W065 0020 W160 0041 9 W570 0026 10 W530 0014 R gulateur P W175 0234 11 W456 0055 Injecteur...

Страница 89: ...NE SERREZ PAS TROP FORT V ri ez pour des fuites en appliquant une solution d eau savonneuse Le volet d air est mal r gl Voir la section r glage du venturi pour le r glage de l ouverture du volet d ai...

Страница 90: ...ettoyez le thermocouple et la connexion la borne de la soupape Remplacez le thermocouple Remplacez la soupape La soupape est d fecteuse Remplacez la soupape La veilleuse br le pas de gaz au br leur pr...

Страница 91: ...t d air est r gl incorrectement Voir la section r glage du venturi pour le r glage de l ouverture du volet d air dans le manual d installation Du carbone se d pose sur la vitre les b ches les roches l...

Страница 92: ...mentation de la veilleuse Le module n est pas mis la terre Assurez le bon polarit du thermocouple si fourni V ri ez si les assemblages de le veilleuse et de la soupape sont bien mis la terre R cepteur...

Страница 93: ...rie fonctionnent si quip La bo te d allumage a t verrouill e Choisissez l une des trois m thodes suivantes pour r initialiser le syst me 1 Pour r initialiser la bo te d allumage lorsqu elle a t verro...

Страница 94: ...s ventilateurs d vacuation les fournaises les s cheuses de linge etc Tous dommages caus s a l appareil la chambre de combustion l changeur de chaleur aux garnitures de laiton ou autres composants par...

Страница 95: ...W415 2884 A 09 21 20 95 FR 16 0 notes...

Страница 96: ...ProduJUT FU EJTUSJCV T QBS 24 Napoleon Road Barrie Ontario Canada L4M 0G8 T l timberwolffireplaces com...

Отзывы: