Dear customer!

Thank you for good choice and purchase of the Timberk infrared 

heater. It will serve long.

The Timberk electric infrared heater is designed for general, 

additional, or local heating of living and production premises 

of all types with ceiling height from 2.5 to 3.5 meters. The 

heater can be installed only on the ceiling or ceiling structural 

elements, or on a wall, where it can be connected to ~220 V, 

50 Hz single-phase power supply. This heating appliance is 

efficient and economic in use thanks to minimum losses of 

electric power.

Please carefully read the Operation Manual before using the infrared heater.
This Operation Manual contains the important information on your safety, 

as well as some recommendations on proper use of the appliance and its 

maintenance.
Keep the Operation Manual along with the warranty certificate, sales 

receipt, and, if possible, cardboard package and packing material.
The purchased infrared may somewhat differ from one described in the 

Manual, but this does not affect the methods of use and operation.

During use of the infrared heater, it is necessary to observe some 

precautions. Improper operation with disregard of precautions may result 

in infliction of harm to health of the user and other people, as well as in 

infliction of damage to their property. 
1. Read all instructions before using the heater.
2. Temperature of radiating boards during operation of the heater may 

reach 340 °C. To avoid burns, do not touch the appliance surface by 

hand and other body parts. It is also necessary to exclude the possibility 

of touching the heater radiating boards by a person (including accidental) 

via proper instructions and allocation of the heater in an inaccessible place.
3. The heater should be placed far from flammable and easily deformable 

objects.
4. The power cord and other objects should not contact hot surfaces of 

the heater.
5. Make sure that the heater body and its radiating boards get cold before 

demounting and placing the heater to the package for long storage. 
6 During demounting of the heater or its movement, take special 

precautions to exclude hits of the appliance and its falling.
7. When the heater is not used for a long time, keep it in dry cool place in 

the factory cardboard package.
8. DO NOT COVER the heater. Do not dry clothes and any other fabrics/

materials on the appliance. This may lead to its overheating, breakdown, or 

infliction of a significant damage to you and/or your property. 

IMPORTANT! 

The important precautions and instructions contained 

in the  manual do not include all possible modes and 

situations which can occur. It should be realized that 

common sense, care and accuracy are the factors 

which cannot be «inbuilt» in any device. These factors 

shall be taken into account by a person being interested 

in the proper operation of the device. The manufacturer 

is not liable if damage to the device or its separate 

parts is caused during transportation, due to incorrect 

installation, voltage fluctuations, and also if any part of 

the device was changed or modified

1. IMPORTANT INFORMATION

2. PRECAUTIONS

IMPORTANT! 

The manufacturer considers this type of failure a non-

guaranteed event.

9. The heater should be connected to the electric mains equipped with an 

automatic circuit breaker.
10. Never connect the heater to the electric mains, if its surface is moist 

(wet). 
11. Never try to repair the heater yourself. This may inflict harm to your 

health and affect the warranty service of the appliance.

Содержание TCH A3 1000

Страница 1: ...Outlook of devices aslo colour scores can be revised without any special advance notices Instruction manual Models TCH A3 1000 TCH A3 1500 TCH A3 2000 Electric ceiling heater infrared heater...

Страница 2: ...including accidental via proper instructions and allocation of the heater in an inaccessible place 3 The heater should be placed far from flammable and easily deformable objects 4 The power cord and...

Страница 3: ...ed to remove it You can do this only if you want to attach the remote control block Remote Control Block is not included in the standard set of heater you can buy it separately Operation principle The...

Страница 4: ...ore than by 5 20 depending on the product category NOTE Heated area in the table is indicated for reference since it depends both on the heater power and on room type ceiling height wall ceiling mater...

Страница 5: ...e floor 4 Install the brackets at distance from each other securing them using a chain or fasteners fig 3 5 Suspend the heater on the brackets according to Fig 3 first securing on edge then another Ma...

Страница 6: ...recommended to keep the heater clean preventing accumulation of dust on it 1 During operation it is necessary to periodically once a year check the electric cable contacts and terminal connectors for...

Страница 7: ...y of the electric cable and replace it if necessary 3 The automatic circuit breaker of the electric mains is faulty 3 Check operability of the automatic circuit breaker of the electric mains and repla...

Страница 8: ...Timberk Timberk 2 5 3 5 220 50 1 2 340 3 4 5 6 7 1 2 www timberk com 8...

Страница 9: ...3 1 2 8 20 21 80 22 23 24 25 9 10 11 12 13 14 15 16 17 18 19 www timberk com 9...

Страница 10: ...berk com Timberk E TCH A3 1000 TCH A3 1500 TCH A3 2000 1000 1500 2000 4 5 6 8 9 1 220 50 220 50 220 50 IP20 IP20 IP20 Class I Class I Class I 2 5 2 7 3 5 2 0 2 9 3 6 50x935x110 50x1360x110 50x1785x110...

Страница 11: ...1 2 2 11 1 8 1 TCH A3 1000 TCH A3 1500 TCH A3 2000 A 78 78 78 B 150 150 150 C 600 600 600 D 2500 2700 3500 E 700 700 700 1 2 3 4 4 2 1 2 4 3 www timberk com 11...

Страница 12: ...1 1 2 1 3 1 4 1 5 1 2 3 1 2 4 3 5 3 6 3 1 220 50 2 1 5 2 1 80 www timberk com 12...

Страница 13: ...1 2 3 4 7 1 1 2 8 9 1 50 0 50 0 80 25 0 2 3 10 0 50 0 3 1 5 2 16 4 5 www timberk com 13...

Страница 14: ...Timberk 10 1 1 1 Timberk 2 2 2 1 1 2 2 3 3 4 4 Timberk 30 30 50 15 85 11 12 4 220 80 25 0 4 www timberk com 14...

Страница 15: ...495 6044266 7 495 6044266 52161 2 30 2007 51318 14 1 2006 4 51318 14 2 2006 5 7 51317 3 3 2008 51317 3 2 2006 6 7 TCRU C IL AB71 B 00079 05 07 2012 04 07 2015 13 10 88000 972 8 637 88 311 111024 5 2 1...

Страница 16: ...Timberk Timberk www btpart ru www timberk com Timberk www btpart ru www timberk com 16...

Страница 17: ...Timberk c 10 www timberk com 17...

Страница 18: ...www timberk com If you found any mistake in this manual please let us know by email listed on www timberk com www timberk com 18...

Страница 19: ...www timberk com 19...

Страница 20: ...www timberk com...

Отзывы: