IM2020
26
ATTENTION!
1. The electric wire connected to the outlet from the power board must have a core cross section
of at least 4 mm
2
(for copper wire).
2. A circuit breaker designed for a rated current of 32A must be installed in the power panel to
protect the wiring from overloads.
THC WS2 9M AERO
1. The curtain is designed to be permanently connected to an alternating current electric network
with a three-phase voltage of 380V ~ (allowable voltage fluctuations from 342V ~ to 418V ~) and
a ground loop.
2. Before connecting the curtain to the electrical network, it is necessary to install an external
control panel connected at the factory. To do this it is necessary to:
- unscrew the screw on the control panel,
- remove the top cover and remote control panel,
- mount the remote control on the wall,
- connect the control cable removed from the curtain to the terminal block of the control panel
according to the scheme from Fig. 5, which is also indicated on the device body.
- Install the panel and the top cover (instructions for installing the remote control and mounting
kit are included).
3. Connection to the stationary power supply network is carried out in accordance with the
scheme indicated in Fig. 5 and on the curtain body.
4. Сable cores going from the power source must be connected to the cores of the power cable
that is removed from the curtain body using a terminal block or special connection clamps that
provide reliable insulation and fixation of the wires (not supplied).
ATTENTION!
1. The electric wire connected to the outlet from the power board must have a core cross section
of at least 1.5 mm
2
(for copper wire).
2. A three-phase circuit breaker designed for a rated current of 16A must be installed in the
power panel to protect the wiring from overloads.