IM2020
22
zone of the curtain. Also, with the heating elements turned off, it can be used in summer to
protect the air-conditioned room from penetrating warm outside air, dust, smoke, insects, etc.
The curtain is designed for operation in closed rooms with an air temperature from -
10°C to +
40°C, with a relative humidity of not more than 93%, in conditions that exclude water drops,
splashes and precipitation (climatic execution
УХЛ 3.1 in accordance with ГОСТ 15150).
4. SPECIFICATIONS
5. Technical parameters
Technical parameters are indicated in table 1
Table 1
Parameter
Unit
THC
WS2
2,5M
AERO
THC WS2
3M AERO
THC WS2
5M
AERO
THC WS2
6M
AERO
THC WS2
9M
AERO
Power supply
V/Hz
220~
/50
220~
/50
220~
/50
220~
/50
380~
/50
Rated current
А
11.4
13.6
22.7
27.2
13.6
Rated power
consumption
W
2500
3000
5000
6000
9000
Power modes
W
0/1250/
2500
0/1500/
3000
0/2500/
5000
0/3000/
6000
0/4500/
9000
Rated fan output
m
3
/h
240
405
500
800
1200
Average outlet air
velocity
m/
sec
7.2
7.9
7
7.5
7.5
Outlet air temperature
increase at maximum
heating
0
С
32
24
32
24
24
Noise level at 5 m
distance
dB(A)
52
52
52
52
52
Moisture protection
class
-
IP20
IP20
IP20
IP20
IP20
Electrical protection
class
-
Class I
Class I
Class I
Class I
Class I
Airflow width / Device
width
mm
260 /480
490 /600
720 /815
1100/ 1120
1570/ 1600
Net weight
kg
4
5
7.4
10.3
14.7
Device dimensions
mm
125х180
х480
168х153
х600
168х153
х815
168х153
х1120
168х153
х1600
Dimensional characteristics
Dimensional characteristics (in mm) are in table 2 according to fig.1
Fig. 1
Содержание AERO I Series