8. MAINTENANCE

•  Before cleaning unplug the conditioner.
•  Cleaning of the indoor unit and remote control board:
•  Indoor unit and remote control board should be cleaned with a dry soft 

cloth.
•  If the indoor unit is too unclean, moisten the cloth with cold water.
•  It  is prohibited to clean the remote control board with moist cloth.
•  In order to avoid the damage of paint or details of the conditioner, do not 

clean it with brushes and do not leave them on the surface of indoor unit.
•  In order to avoid the damage of surface or deformation of the conditioner 

details, do not clean it with petrol, solvents, cleaning powders or other 

chemically active substances.
•  Before a sustained interruption in the conditioner work:
•  Turn the conditioner on for several hours in the FAN mode. It will allow 

you to dry its inner cavities
•  Unplug the conditioner. Remove the batteries from the remote control 

board. 
•  Checks before starting:
•   Make sure that an air filter is installed.
•  Make sure that air inlet and outlet grilles of the outdoor unit are not 

blocked by foreign objects.
•  Cleaning of air filter
•  Air filter cleans the air entering the conditioner from dust and foreign 

particles. If the filter is contaminated, the conditioner capacity decreases 

sharply.
•  If the conditioner is operated permanently, the filter should be cleaned 

once per two weeks.

•  If the conditioner is installed in a room with dusty atmosphere, then the 

air filter should be cleaned more often.
•  To remove the filter, open the indoor unit panel.
•  Remove air filters. Clean the filter with a vacuum cleaner or rinse it in 

clean water. If the filter is contaminated heavily, clean it with a soft brush 

and wash in diluted washing solution, then dry it in a cool place.
•  While cleaning the filter with the vacuum cleaner, hold it with contaminated 

surface up. While washing the filter in water, hold it with contaminated 

surface down.
•  Do not dry the filter in the sun or near a fire.
•  Set the air filter to initial position and close the panel.

1 °С an hour  from the specified one within two hours. After 10 hours of 

operation the conditioner will turn off automatically.

Regulation of treated air flow direction

Regulating the position of deflectors (blinds), set the direction of treated 

air flow ensuring uniform distribution of temperature and the most comfort 

conditions in the room. To change the position of deflectors, use the 

«SWING» button.

9. TROUBLESHOOTING

In case of emergency, please, use the troubleshooting methods shown in 

tables. If it is impossible to solve problems with these methods, apply to 

the service center.
Failures and their possible reasons:

Failure

Possible reason

Actions

The conditioner does 

not work

Interruptions in power supply

Wait for restoration of power 
supply

Batteries in the remote control 
board are low

Replace the batteries

Time of tuming on is set by 
the timer

Wait till the conditooner turns 
on by the timer or cancel the 
timer setting

Insufficient cooling or 

heating capacity

The set air temperature is too 
high or too low

Set the air temperature 
correctly

The air filter is clogged with dust

Clean the air filter

Foreign objects block the air intel 
and retum air grillages of the 
outdoor unit

Remove foreign objects

The conditioner works, 

but does not cool or 

heat the room 

A three-minute delay of 
compressor tuming on

Wait a little

The air temperature is set 
incorrectly

Set the temperature correctly

Содержание AC TIM 07H S15

Страница 1: ...stem Outlook of devices aslo colour scores can be revised without any special advance notices Electrical air conditioner split system outdoor unit AC TIM 07H S15 AC TIM 09H S15 AC TIM 12H S15 AC TIM 1...

Страница 2: ...cialized service center for further explanations The article has a label with all the needed technical data and other useful information about the appliance Use the appliance only for its intended pur...

Страница 3: ...ditioner during a lighting storm 13 Always unplug the conditioner when it is not used 14 Before cleaning and maintenance of the conditioner unplug it Cleaning and maintenance should be performed in ac...

Страница 4: ...7 Rated power consumption heating W 632 773 1072 1461 1967 Power supply V Hz 220 240 50 220 240 50 220 240 50 220 240 50 220 240 50 Rated power current cooling heating W 3 0 2 9 3 8 3 6 5 2 5 0 7 5 6...

Страница 5: ...630 1100 1300 Operating temperature range cooling C 18 43 18 43 18 43 18 43 18 43 Operating temperature range heating C 7 24 7 24 7 24 7 24 7 24 Net weight indoor unit kg 6 2 6 2 7 8 9 3 9 3 Net weig...

Страница 6: ...r tube for gas freon connection line 8 Tube for condensate removal 9 Air outlet grille of the outdoor unit 10 Conditioner unit for outdoor installation 11 Air intake grilles of the outdoor unit Remote...

Страница 7: ...not insert used batteries or batteries of various types If the conditioner is not used for a long time remove batteries from the board or else electrolyte may leak and damage the board In normal opera...

Страница 8: ...ors Automatic mode sele ction Automatically maintained temperature if 20 then HEAT mode shall be turned on 23 if 20 26 then DRY mode shall be turned on 18 if 26 then COOL mode shall be turned on 23 AS...

Страница 9: ...water If the filter is contaminated heavily clean it with a soft brush and wash in diluted washing solution then dry it in a cool place While cleaning the filter with the vacuum cleaner hold it with...

Страница 10: ...ehouse at the temperature not lower than 30 Service life of the appliance is 10 years provided that the respective installation and operation rules are observed Date of the conditioner manufacture is...

Страница 11: ...www timberk om 11 Timberk 1 1 11 2 12 3 13 4 15 5 15 6 15 7 17 8 19 1...

Страница 12: ...www timberk om 12 2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23...

Страница 13: ...U kW 7050 2 07 9080 2 66 12300 3 61 17980 5 27 23990 7 04 BTU kW 7850 2 30 9650 2 83 13280 3 89 18150 5 32 24300 7 13 642 811 1120 1621 2137 632 773 1072 1461 1967 220 240 50 220 240 50 220 240 50 220...

Страница 14: ...24H S15 01 1 4 3 8 1 4 3 8 1 4 3 8 1 4 1 2 3 8 5 8 15 15 15 15 15 5 5 5 5 5 18 43 18 43 18 43 18 43 18 43 7 24 7 24 7 24 7 24 7 24 430 510 630 1100 1300 6 2 6 2 7 8 9 3 9 3 23 3 23 4 30 37 8 40 8 2 8...

Страница 15: ...www timberk om 15 8 7 9 3 4 2 5 6 1 11 10 4 1 2 3 4 5 6 7 8 9 10 11 5 1 1 1 2 1 1 1 1 1 6 1 2 3 4 2...

Страница 16: ...www timberk om 16 1 2 TEMP 3 SET 4 ON OFF Power b c d e f a b c d e f 3 12 ON OFF Power 13 TEMP 14 FAN Auto High Middle Low Auto Low 15 SWING 16 TIMER TEMP 4 12 13 14 17 15 20 16 19 18...

Страница 17: ...www timberk om 17 17 SUPER 18 ECO Economic 2 2 19 SLEEP Night Care 1 1 10 20 MODE LR03 8 SMART MODE 1 2 7...

Страница 18: ...6 18 26 23 Smart Smart Temp 2 2 2 COOL HEAT FAN 1 ON OFF 2 MODE COOL HEAT FAN 3 TEMP 4 FAN Smart 5 ON OFF DRY ON OFF MODE DRY ON OFF SUPER TURBO TURBO TIMER TIMER TEMP TIMER TIMER TEMP TIMER SLEEP SLE...

Страница 19: ...www timberk om 19...

Страница 20: ...www timberk om 20 Timberk Timberk www btpart ru www timberk com Timberk www btpart ru Timberk www btpart ru...

Страница 21: ...www timberk om 21 Timberk c 10...

Страница 22: ...www timberk om 22 www timberk com If you found any mistake in this manual please let us know by email listed on www timberk com...

Страница 23: ...www timberk om 23...

Страница 24: ...www timberk com...

Отзывы: