Timberk AC TIM 07H S15 Скачать руководство пользователя страница 7

www.timberk.com • Electric air conditioner

7

the conditioner on and off (set the time by pressing “TEMP» buttons up and 

down). If the conditioner is off, you may set the time for automatic turning 

on in a set time interval. And vice versa, if the conditioner is on, you may set 

the time for automatic turning off. Before activation of the Timer function 

you may specify the needed settings.
17.Button «SUPPER». Using this button, you may turn the turbo mode on 

and off. In this mode the conditioner shows the maximum cooling (in cool 

mode) or heating (in heat mode) capacity.
18.Button «ECO» (Economic). Using this button, you may turn the 

economic mode on and off. In this mode temperature will increase (in cool 

mode) or decrease (in heat mode) slightly – by 2°С from the specified one. 
19.Button «SLEEP» (Night Care). Using this button, you may turn the sleep 

mode on and off. In this mode, if working for cooling, the conditioner will 

increase temperature by 1 °С from the specified one within two hours. 

If working for heating, the conditioner will decrease temperature by 1 °С 

from the specified one within two hours. After 10 hours of operation the 

conditioner will turn off automatically.
20.Button for selection of operating mode – «MODE». Using this button, 

you may select a needed operating mode: AUTO, COOL, DRY, HEAT, FAN.

Indication of the control board display shall correspond to selected modes.

Work with remote control board
Mounting and replacement of batteries: mount two LR03 alkaline batteries, 

according to polarity indicated on the remote control board.
In order to avoid malfunction of the remote control board do not insert used 

batteries or batteries of various types.
If the conditioner is not used for a long time, remove batteries from the 

board or else electrolyte may leak and damage the board.
In normal operation of the conditioner average service life of batteries will 

be about a half-year.
Replace batteries, if command receiving is not confirmed with an audio 

signal, or if the display does not show a sign of command transfer. When 

generating commands from the remote control board, point an IR-radiator 

at a remote-control signal receiver situated on the indoor unit. Hold the 

remote control board at the distance of no more than 8 m from the indoor 

unit. The remote control board will not work, if there are any curtains, doors 

or other things between it and the indoor unit. Protect the board from water 

and exposure to direct sunlight and heat sources.

Fig. 4

а) Power supple indicator
b) Heating mode indicator
c) Cooling mode indicator
d) Temperature indicator 
e) Timer indicator
f) Operation indicator

 *use of particular indicators depends on model and series.
** design of indicator symbols may differ depending on model 

and series.

12

13

14

17

15

20

16
19

18

a         b       c        d           e        f

Fig. 3

12.Button «ON/OFF» (Power). Using this button, you may turn the 

conditioner on or off.
13.Buttons «TEMP» (increase/decrease). Using this button, you may set 

needed air temperature indoors.
14.Button «FAN». Using this button, you may select rotation speed of the 

indoor unit fan: «Auto», «High», «Middle», «Low».
In “Auto” mode the fan speed will change automatically. In dry mode the 

fan speed will remain unchanged – “Low”.

15.Button «SWING». Using this button, you may regulate position of air-

outlet blinds and forward treated air up and down.
16.Button «TIMER». Pressing this button, you may set the time for turning 

Description of remote control board

Содержание AC TIM 07H S15

Страница 1: ...stem Outlook of devices aslo colour scores can be revised without any special advance notices Electrical air conditioner split system outdoor unit AC TIM 07H S15 AC TIM 09H S15 AC TIM 12H S15 AC TIM 1...

Страница 2: ...cialized service center for further explanations The article has a label with all the needed technical data and other useful information about the appliance Use the appliance only for its intended pur...

Страница 3: ...ditioner during a lighting storm 13 Always unplug the conditioner when it is not used 14 Before cleaning and maintenance of the conditioner unplug it Cleaning and maintenance should be performed in ac...

Страница 4: ...7 Rated power consumption heating W 632 773 1072 1461 1967 Power supply V Hz 220 240 50 220 240 50 220 240 50 220 240 50 220 240 50 Rated power current cooling heating W 3 0 2 9 3 8 3 6 5 2 5 0 7 5 6...

Страница 5: ...630 1100 1300 Operating temperature range cooling C 18 43 18 43 18 43 18 43 18 43 Operating temperature range heating C 7 24 7 24 7 24 7 24 7 24 Net weight indoor unit kg 6 2 6 2 7 8 9 3 9 3 Net weig...

Страница 6: ...r tube for gas freon connection line 8 Tube for condensate removal 9 Air outlet grille of the outdoor unit 10 Conditioner unit for outdoor installation 11 Air intake grilles of the outdoor unit Remote...

Страница 7: ...not insert used batteries or batteries of various types If the conditioner is not used for a long time remove batteries from the board or else electrolyte may leak and damage the board In normal opera...

Страница 8: ...ors Automatic mode sele ction Automatically maintained temperature if 20 then HEAT mode shall be turned on 23 if 20 26 then DRY mode shall be turned on 18 if 26 then COOL mode shall be turned on 23 AS...

Страница 9: ...water If the filter is contaminated heavily clean it with a soft brush and wash in diluted washing solution then dry it in a cool place While cleaning the filter with the vacuum cleaner hold it with...

Страница 10: ...ehouse at the temperature not lower than 30 Service life of the appliance is 10 years provided that the respective installation and operation rules are observed Date of the conditioner manufacture is...

Страница 11: ...www timberk om 11 Timberk 1 1 11 2 12 3 13 4 15 5 15 6 15 7 17 8 19 1...

Страница 12: ...www timberk om 12 2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23...

Страница 13: ...U kW 7050 2 07 9080 2 66 12300 3 61 17980 5 27 23990 7 04 BTU kW 7850 2 30 9650 2 83 13280 3 89 18150 5 32 24300 7 13 642 811 1120 1621 2137 632 773 1072 1461 1967 220 240 50 220 240 50 220 240 50 220...

Страница 14: ...24H S15 01 1 4 3 8 1 4 3 8 1 4 3 8 1 4 1 2 3 8 5 8 15 15 15 15 15 5 5 5 5 5 18 43 18 43 18 43 18 43 18 43 7 24 7 24 7 24 7 24 7 24 430 510 630 1100 1300 6 2 6 2 7 8 9 3 9 3 23 3 23 4 30 37 8 40 8 2 8...

Страница 15: ...www timberk om 15 8 7 9 3 4 2 5 6 1 11 10 4 1 2 3 4 5 6 7 8 9 10 11 5 1 1 1 2 1 1 1 1 1 6 1 2 3 4 2...

Страница 16: ...www timberk om 16 1 2 TEMP 3 SET 4 ON OFF Power b c d e f a b c d e f 3 12 ON OFF Power 13 TEMP 14 FAN Auto High Middle Low Auto Low 15 SWING 16 TIMER TEMP 4 12 13 14 17 15 20 16 19 18...

Страница 17: ...www timberk om 17 17 SUPER 18 ECO Economic 2 2 19 SLEEP Night Care 1 1 10 20 MODE LR03 8 SMART MODE 1 2 7...

Страница 18: ...6 18 26 23 Smart Smart Temp 2 2 2 COOL HEAT FAN 1 ON OFF 2 MODE COOL HEAT FAN 3 TEMP 4 FAN Smart 5 ON OFF DRY ON OFF MODE DRY ON OFF SUPER TURBO TURBO TIMER TIMER TEMP TIMER TIMER TEMP TIMER SLEEP SLE...

Страница 19: ...www timberk om 19...

Страница 20: ...www timberk om 20 Timberk Timberk www btpart ru www timberk com Timberk www btpart ru Timberk www btpart ru...

Страница 21: ...www timberk om 21 Timberk c 10...

Страница 22: ...www timberk om 22 www timberk com If you found any mistake in this manual please let us know by email listed on www timberk com...

Страница 23: ...www timberk om 23...

Страница 24: ...www timberk com...

Отзывы: