3. SPECIFICATIONS

Model

AC TIM 07H S15

AC TIM 09H S15

AC TIM 12H S15

AC TIM 18H S15

AC TIM 24H S15

Indoor unit

AC TIM 07H S15

AC TIM 09H S15

AC TIM 12H S15

AC TIM 18H S15

AC TIM 24H S15

Outdoor unit

AC TIM 07H S15-01

AC TIM 09H S15-01

AC TIM 12H S15-01

AC TIM 18H S15-01

AC TIM 24H S15-01

Capacity (cooling)  BTU (kW)

7050 (2,07)

9080 (2,66)

12300 (3,61)

17980 (5,27)

23990 (7,04)

Capacity (heating)  BTU (kW)

7850 (2,30)

9650 (2,83)

13280 (3,89)

18150 (5,32)

24300 (7,13)

Rated power consumption (cooling) 

(W)

642 

811 

1120 

1621 

2137 

Rated power consumption (heating) 

(W)

632 

773 

1072 

1461 

1967 

Power supply, V/Hz

220-240~/50

220-240~/50

220-240~/50

220-240~/50

220-240~/50

Rated power current (cooling/

heating) (W)

3,0/2,9 

3,8/3,6 

5,2/5,0

7,5/6,8 

9,9/9,1 

Air circulation (indoor unit) m

3

/h

430

430

530

780

780

Air circulation (outdoor unit) m

3

/h

1415

1415

2040

2340

3350

Noise level (indoor unit) dB(A)

32-36

32-36

34-39

44-48

44-48

Noise level (outdoor unit) dB(A)

50

52

55

58

60

Refrigerant

R410A

R410A

R410A

R410A

R410A

Energy efficiency (cooling/heating)

A/A

A/A

A/A

A/A

A/A

Electrical protection class

I class

I class

I class

I class

I class

Degree of protection against 

moisture (indoor unit)

IPX0

IPX0

IPX0

IPX0

IPX0

Degree of protection against 

moisture (outdoor unit)

IPX4

IPX4

IPX4

IPX4

IPX4

Содержание AC TIM 07H S15

Страница 1: ...stem Outlook of devices aslo colour scores can be revised without any special advance notices Electrical air conditioner split system outdoor unit AC TIM 07H S15 AC TIM 09H S15 AC TIM 12H S15 AC TIM 1...

Страница 2: ...cialized service center for further explanations The article has a label with all the needed technical data and other useful information about the appliance Use the appliance only for its intended pur...

Страница 3: ...ditioner during a lighting storm 13 Always unplug the conditioner when it is not used 14 Before cleaning and maintenance of the conditioner unplug it Cleaning and maintenance should be performed in ac...

Страница 4: ...7 Rated power consumption heating W 632 773 1072 1461 1967 Power supply V Hz 220 240 50 220 240 50 220 240 50 220 240 50 220 240 50 Rated power current cooling heating W 3 0 2 9 3 8 3 6 5 2 5 0 7 5 6...

Страница 5: ...630 1100 1300 Operating temperature range cooling C 18 43 18 43 18 43 18 43 18 43 Operating temperature range heating C 7 24 7 24 7 24 7 24 7 24 Net weight indoor unit kg 6 2 6 2 7 8 9 3 9 3 Net weig...

Страница 6: ...r tube for gas freon connection line 8 Tube for condensate removal 9 Air outlet grille of the outdoor unit 10 Conditioner unit for outdoor installation 11 Air intake grilles of the outdoor unit Remote...

Страница 7: ...not insert used batteries or batteries of various types If the conditioner is not used for a long time remove batteries from the board or else electrolyte may leak and damage the board In normal opera...

Страница 8: ...ors Automatic mode sele ction Automatically maintained temperature if 20 then HEAT mode shall be turned on 23 if 20 26 then DRY mode shall be turned on 18 if 26 then COOL mode shall be turned on 23 AS...

Страница 9: ...water If the filter is contaminated heavily clean it with a soft brush and wash in diluted washing solution then dry it in a cool place While cleaning the filter with the vacuum cleaner hold it with...

Страница 10: ...ehouse at the temperature not lower than 30 Service life of the appliance is 10 years provided that the respective installation and operation rules are observed Date of the conditioner manufacture is...

Страница 11: ...www timberk om 11 Timberk 1 1 11 2 12 3 13 4 15 5 15 6 15 7 17 8 19 1...

Страница 12: ...www timberk om 12 2 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23...

Страница 13: ...U kW 7050 2 07 9080 2 66 12300 3 61 17980 5 27 23990 7 04 BTU kW 7850 2 30 9650 2 83 13280 3 89 18150 5 32 24300 7 13 642 811 1120 1621 2137 632 773 1072 1461 1967 220 240 50 220 240 50 220 240 50 220...

Страница 14: ...24H S15 01 1 4 3 8 1 4 3 8 1 4 3 8 1 4 1 2 3 8 5 8 15 15 15 15 15 5 5 5 5 5 18 43 18 43 18 43 18 43 18 43 7 24 7 24 7 24 7 24 7 24 430 510 630 1100 1300 6 2 6 2 7 8 9 3 9 3 23 3 23 4 30 37 8 40 8 2 8...

Страница 15: ...www timberk om 15 8 7 9 3 4 2 5 6 1 11 10 4 1 2 3 4 5 6 7 8 9 10 11 5 1 1 1 2 1 1 1 1 1 6 1 2 3 4 2...

Страница 16: ...www timberk om 16 1 2 TEMP 3 SET 4 ON OFF Power b c d e f a b c d e f 3 12 ON OFF Power 13 TEMP 14 FAN Auto High Middle Low Auto Low 15 SWING 16 TIMER TEMP 4 12 13 14 17 15 20 16 19 18...

Страница 17: ...www timberk om 17 17 SUPER 18 ECO Economic 2 2 19 SLEEP Night Care 1 1 10 20 MODE LR03 8 SMART MODE 1 2 7...

Страница 18: ...6 18 26 23 Smart Smart Temp 2 2 2 COOL HEAT FAN 1 ON OFF 2 MODE COOL HEAT FAN 3 TEMP 4 FAN Smart 5 ON OFF DRY ON OFF MODE DRY ON OFF SUPER TURBO TURBO TIMER TIMER TEMP TIMER TIMER TEMP TIMER SLEEP SLE...

Страница 19: ...www timberk om 19...

Страница 20: ...www timberk om 20 Timberk Timberk www btpart ru www timberk com Timberk www btpart ru Timberk www btpart ru...

Страница 21: ...www timberk om 21 Timberk c 10...

Страница 22: ...www timberk om 22 www timberk com If you found any mistake in this manual please let us know by email listed on www timberk com...

Страница 23: ...www timberk om 23...

Страница 24: ...www timberk com...

Отзывы: