32
Unscrew the safety thermostat cover (1) and check
whether the needle is (2) retracted or extended. If the
needle is pulled out, push the pin and restart the stove.
If the needle is retracted, or if it can not be retracted,
and the stove is still reporting the same mistake call the
service.
Error due to a mulfunction of safty-pressure
controls.
Safety pressure switch is used to check the underpressure in a smoke drain. If the under pressure
is insufficient the stove will stop working or it will not be able to start. When mulfunctioning of safety
pressure controle is detected, the display message will appear as shown in the following figure (AL
8
FAILURE DEPRESS
) and alternately will be changed with a message that reports a malfunction
(
ALLARME ATTIVO
).
Malunctioning of the pressure switch can occur if the stove seal leaks, if the chimney or smoke
drain are clogged, or if the fan speed is too low. In the event that the stove seal leaks, it is
necessary to check that the door braids and the ashtray are well placed, that they are not
accidentally stucked off etc. In case braids are placed correctly, please check the chimney. The
chimney is checked by putting the flame close to the moke drain which is on the wall, and if the
flame turns toward the smoke drain, that means that the chimney is in order, if it returnes to the
room, or if it stays still, then the chimney is out of order. In this case, call the chimney sweep. How
to clean the stove properly is described in the section maintenance.
Non-functional probe for measuring water temperature.
In case
of malfunction of the probe for measuring the water temperature, it is
necessary to call a qualified technician. The probe must be
immediately replaced so that the stove could regularly continue
working.
Too high water temperature.
In case
this error occures it’s
necessary to shut down the stove and call the service technician to
eliminate malfunction.
Содержание rittium 14 hydro
Страница 1: ...RITTIUM 14 HYDRO Owners s manual INSTALATION ADJUSTMENT AND OPERATING INSTRUCTION EN 14785 2006...
Страница 2: ...2...
Страница 37: ...37 Distributor authorized service...
Страница 38: ...38 13 ANNEX A CONECTING TO A HEATING INSTALATION CHEME...
Страница 39: ...39 14 ANNEX B CONNECTING TO CONTROL UNIT CHEME...
Страница 43: ...43...