9. OPERATION INFO

 

 

       Status of stove operation can be verified with the help KEYS. Pressing this key is posible to 
see the current temperature of exhaust gases, stove operating modes, pellet  insertion, the 
remaining time left untill next operation left. 

Pressing and holding the help key 1 there will be shown the                     
following screen layout. Here you can find information as well as 
the current

  

pellet loading. Just by moving your finger of the key, 

the

 

display will return to the main menu

.

 

 

Pressing  and  holding  the  key  2,  there  will  appear  a  following 
screen layout. Here you can find information about the temperature 
of  exhaust  gases,  mode,  stove,  fan  speeds  for  sewers  and  heat 
dissipation  (optional).  Just  by  moving  your  finger  of  the  key,  the 
display will return to the main menu.

 

 

 

Pressing and holding the key 5 you will get this screen layout.  
This option is intended for stove for central heating, therefore in an 
ordinary stove has no purpose. Here you can find information on a 
selected  water  temperature,  and  pressure  in  the  boiler.  Just  by 
moving  your  finger  of  the  key,  the  display  will  return  to  the  main 
menu

.

 

 

Pressing and holding the key 6 will get this screen layout. Here you 
can  find  information  on  time  remaining  until  the  next  mode 
becomes active. Just by moving your finger of the key, the display 
will return to the main menu.

 

 

 

 

 

10. POTENTIAL ERRORS IN OPERATION 

In each stove malfunction indicator will blink next to a warning sign and the stove will automatically 
stop working. There are several errors that can occur in stove operation, which will be described in 
detail below. 

 

Error  due  the  lack  of  electricity  or  forced  disconecting  form 
power source.

 Due the lack of electricity or forced disconecting form 

power source, opperation error will appear which will be indicated by 
Error  indication  light.  Mesagges 

AL1  BLACK  OUT

  and   

ALLARME 

ATTIVO

 will be

 

displayed.

 

Содержание rittium 14 hydro

Страница 1: ...RITTIUM 14 HYDRO Owners s manual INSTALATION ADJUSTMENT AND OPERATING INSTRUCTION EN 14785 2006...

Страница 2: ...2...

Страница 3: ...nd mode settings 14 8 SETTINGS 15 8 1 Clock settings 15 8 2 Timer settings 15 8 2 1 How to turn the timer on 16 8 2 2 Daily programmer 17 8 2 3 Weekly programmer 18 8 2 4 Weekend programmer 22 8 3 Lan...

Страница 4: ...such as carbon dioxide sulfur dioxide and mercury and the burning leaves only 0 5 1 of ash Wood pellet is made of 100 natural materials and contains no added binders chemicals or additives Compared wi...

Страница 5: ...on the main switch Chapter basic parts of the stove in the room where stove is placed it is necessary to ensure a permanent supply of fresh air stove must be installed in accordance with these manual...

Страница 6: ...ical power during the operation W 55 160 Electrical power during the initialization W 400 450 Efficiency 92 37 Reduced power nominal air water kW 4 3 1 3 3 Fuel consumption nominal Kg h 3 475 Fuel con...

Страница 7: ...et 4 Ashtray door 16 Safety valves 5 Door of the firebox 17 Water outlet 1 6 Glass on the door 18 Water inlet 1 7 Door handle 19 Drain valve 8 Combustion pot 20 Socket 9 Storage 21 Main switch 10 Cove...

Страница 8: ...ere the stove is placed in order to provide a optimal combustion Place the stove as close as possible to a smoke drain where is also a power connection The stove shuld be away from any possible obstac...

Страница 9: ...s for correct opperation of the stove Draft depends on chimney conditions and outside weather One of most easiest ways to check the quality od chimney draft is to use a candle like it is shown on pict...

Страница 10: ...With the stove you get and the power cord Stove is connected to the power source voltage of 230V and 50Hz Stove must be connected only to the required socket Figure 5 shows how the stove is connected...

Страница 11: ...ing which of the element is currently on Beside of the symbols for the pellet the indicator will be periodically turned on and off depending on whether the engine for the insertion of pellets is on or...

Страница 12: ...ture setting buttons 2 remote control indicator 3 mode keys 4 transmitter 5 cover Take off the cover and set the battery according to the symbols indicated in the bottom of the remote Symbol goes with...

Страница 13: ...at the same time turns stove ON and OF Pressing the buttons 1 and 2 is being set a wanted temperature Buttons 5 i 6 are there for mode settings Settings of temperature and mode are described accuratel...

Страница 14: ...ing for some more time The next displayed message will be LIGHTER WAIT indicating that the lighter is ON and that it s being warmed up in order to get the pellets inflamed Stove will load the amount o...

Страница 15: ...Setting the operation mode of the stove is done by pressing the key 6 Operating mode can be changed from P1 to P5 Operating modes can be changed by pressing keys 5 and 6 which will be followed by the...

Страница 16: ...r the days in a week with pressing the key 5 settings will change in a following order Hour setting minutes days in a month months and years Parameter setting are being done by pressing the keys 1 i 2...

Страница 17: ...NABLE CHRONO Then again press the key 3 set and a message will appear off m 2 1 01 ENABLE CHRONO which means that the timer is turned off and setting indicator will continue blinking Pressing the keys...

Страница 18: ...in presses the key 5 and the on display will show up the message m 2 2 PROGRAM DAY Afterward pressed the key 3 set and there will be displayed off m 2 2 01 CHRONO DAY With the keys 1 and 2 switch the...

Страница 19: ...nd you will get a displayed message menu 01 SET CLOCK Afterward you need to press the key 5 twice and on display will be written menu 02 SET CHRONO Pressing the key 3 set you access the timer setting...

Страница 20: ...eys 5 and 6 to scroll through menus and the keys 1 and 2 to change the parameters The menu is shown in the following table Time can be set in intervals of 10 minutes m 2 3 02 START PROG 1 m 2 3 03 STO...

Страница 21: ...off 00 00 23 50 off 00 00 23 50 off on m 2 3 14 TUESDAY PROG 2 m 2 3 15 WEDNESDA PROG 2 m 2 3 16 THURSDAY PROG 2 m 2 3 17 FRIDAY PROG 2 off on off on off on off on m 2 3 18 SATURDAY PROG 2 m 2 3 19 SU...

Страница 22: ...ay The third starting up is every day except Saturday and Sunday from 5 pm and turning off at 10 pm On Saturday and Sunday are the stove is starting up at 8 am and turning off at 11pm Parameters shoul...

Страница 23: ...press the key 3 set and you will get a displayed message off m 2 4 01 CHRONO WEEK END With the keys 1 and 2 switch the program to on in order to activate a weekly timer Use the keys 5 and 6 to scroll...

Страница 24: ...ed message menu 01 SET CLOCK Afterward you need to press the key 5 three times and on display will be written menu 04 SELECT LANGUAGE Pressing the key 3 set you access the language setting menu and di...

Страница 25: ...f the fuel It s function is to turn off the stove automatically as soon as the required temperature has been achieved Stand by mode is set in the way that as soon as the difference in a temperature is...

Страница 26: ...lerts Speaker serves to avert the malfunction of the alarm by beeping The speaker can be turned on or off Turning the speaker on is done as follow Press the key 3 set and you will get a displayed mess...

Страница 27: ...menu 01 ADJUST BLOWERS Afterward you need to press the key 5 six times and on display will be written menu 07 MODE LOAD INITIAL By pressing the key 3 set you access the menu for the initial loading of...

Страница 28: ...d menu 01 messages ADJUST blowers Then press the button for 5 seven times after you ll be shown the message menu 08 STATE STOVE Pressing 3 set you access the menu for print the messages about the stov...

Страница 29: ...out This option is intended for stove for central heating therefore in an ordinary stove has no purpose Here you can find information on a selected water temperature and pressure in the boiler Just by...

Страница 30: ...the message appeared previously Too high temperature of exhaust gases If the exhaust gases temperature is not lowered and when the message HOT EXHAUSTis being displayed the stove will continue workin...

Страница 31: ...up the stove for several times If you fail starting it that way call the service in charge Malfunction of the lighter can be noticed when starting the stove there are no sparks or glowing pellets on s...

Страница 32: ...n are clogged or if the fan speed is too low In the event that the stove seal leaks it is necessary to check that the door braids and the ashtray are well placed that they are not accidentally stucked...

Страница 33: ...aned at least 30 minutes after arresting in order to avoid burns on contact with the hot parts of the stove When cleaning with a damp cloth or water be careful not to get water to the electrical compo...

Страница 34: ...d then again rewiped with a dry cloth Weekly cleaning Beside daily cleaning you need to empty an ash tray once in a week or more frequenty if bigger quantity of pellet is being used Monthly cleaning I...

Страница 35: ...For setting the lid apply the procedure backwards Watch out for the seal which is located under the cover in order to avoid possible damages Cleaning of the inspection opening is being done by removi...

Страница 36: ...uly completed guarantee certificate and the shop s receipt The warranty for this product is 24 months TIM SISTEM is obliged to provide spare parts in due time after the stove is no longer produced Thi...

Страница 37: ...37 Distributor authorized service...

Страница 38: ...38 13 ANNEX A CONECTING TO A HEATING INSTALATION CHEME...

Страница 39: ...39 14 ANNEX B CONNECTING TO CONTROL UNIT CHEME...

Страница 40: ..._____ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________...

Страница 41: ...____________________________ ________________________________________________________________________ ________________________________________________________________________ _________________________...

Страница 42: ...__________________ __________________________________________________________________________________ __________________________________________________________________________________ _______________...

Страница 43: ...43...

Страница 44: ...44 TIM SISTEM d o o Prva industrijska No 9 22 330 Nova Pazova Srbija tel fax 381 22 32 80 76 e mail office timsistem rs www tmisistem rs...

Отзывы: