30
Exhaust gases temperature measuring probe failure.
If
message
AL2 SONDA FUMI
appears
,
you should check whether the
probe for measuring the temperature of exhaust gases is well
connected. If the probe is discoinnected, call the sevice in charge
to
change it. The probe cannot be adjusted or reconnected.
Also, the probe testing is done in the following way. Press key 2 and
hold it untill the following screen layout shows: Number 373
o
C
indicates thet the probe for measuring exhausting gases is
disfunctional or wrongly connected. For this kind of a problem, please
call the service in charge.
High temperature of exhausting gases
. When the exhaust
gases
temperature exceeds a factory-set value, the following message
appears on the screen HOT EXHAUST. The stove will automatically
switch to lower operation mode and it will reduce the temperature of the
exhaust gases. If this message appears too often call the service in
charge. The stove can be used in lower operating modes those in
which the message appeared previously.
Too high temperature of exhaust gases.
If the exhaust
gases’
temperature is not lowered, and when the message HOT EXHAUSTis
being displayed, the stove will continue working in a minimal regime until
the temperature is lower
than 280 ° C. If the temperature exceeds 280 °
C, the stove will report an error AL3 HOT SMOKE.
Error caused by malfunctioning of the fan exhaust gases fan.
The display message will appear as shown in the following figure (AL 4
FAN FAILURE) and alternately will be changed with a message that
reports a malfunction (Allarme ATTIVO).
Error may occur due to a fan blocked or jammed, as well as due to a
mulfunctioning of the contacts used for powering the fan or breakage of
cables, which measure the numer of fan rotations. If this error occurs please contact the service in
charge. Malfunction of the fan can be observed by pressing and holding the key 2, so that in the
place where should be written a fan speed number, sta
nds 000.
Error caused by inability to start the stove.
The display message will appear as shown in the
following figure (
AL 5 NO LIGHTIN-)
and alternately will be changed with a message that reports a
malfunction (
Allarme ATTIVO
).
Содержание rittium 14 hydro
Страница 1: ...RITTIUM 14 HYDRO Owners s manual INSTALATION ADJUSTMENT AND OPERATING INSTRUCTION EN 14785 2006...
Страница 2: ...2...
Страница 37: ...37 Distributor authorized service...
Страница 38: ...38 13 ANNEX A CONECTING TO A HEATING INSTALATION CHEME...
Страница 39: ...39 14 ANNEX B CONNECTING TO CONTROL UNIT CHEME...
Страница 43: ...43...