background image

 

Dear Customer,

 

 

We appreciate your trust wested in us and decision to use TIM SISTEM product.

 

You  have  invested  in  energy-efficient  and  high-quality  product  -  NORTH  HYDRO  wood 

burning cooker.

 

Your  purchase  will  provide  you  long-term  clean  and  comfortable  heating  with  minimal 

maintenance.

 

Please read these instructions carefully and completely.

 

It’s purpose is to inform you about the installation, operation and maintenance of your stove. 

Keep it handy and refer to it as needed. You will find in it information that will be useful now 

and in the years to come.

 

Make sure that when installing the stowe all security standards have been respected  and 

that all gas pipes, connections between tubes and pipes and walls are connected properly.

 

Disregarding these standards and negligence during installation can damage your property 

or put your health and life in danger!

 

Set your cooker to a safe place, away from the frequent passages and doors, somewhere 

near chimney and chimney connection.

 

 

We wish you manypleasant moments with NORTH HYDRO.

 

 

 

 

TIM SISTEM d.o.o.

 

 

 

 

 

 

 

 

 

Содержание NORTH HYDRO

Страница 1: ...on and lighting 9 Handling the cooker operation 11 Authomatic regulation of stove s operation 12 Installing the cooker into the sistem for water heating 13 Installation on closed central heating syste...

Страница 2: ...your stove Keep it handy and refer to it as needed You will find in it information that will be useful now and in the years to come Make sure that when installing the stowe all security standards have...

Страница 3: ...dling it Do not allow children to handle and play near the cooker Only spare partes reccomended and allowed by the manufacturer should be installed on the cooker You must not make any changes on the c...

Страница 4: ...position 12 16l volume made of boiler plates tickness prescribed by standards This kind of a manufacture prolongs life of the boiler Water connections are 1 Working surface of the cooker is made of a...

Страница 5: ...on 13 O2 mg Nm 3 4271 Chimney connection mm 150 Chimney connection position Top right left Rear right left Consuption by nominal power kg h 3 8 Emission temperature C 162 Required draft Pa 10 14 Stor...

Страница 6: ...sure adequate tightness and flow of smoke from the stove to the chimney Flue pipe must not be drawn too deeply into the chimney that would reduce the cross sectional area and thus undermined draft in...

Страница 7: ...d if it s located on the external walls of the building it s recommended insulation chimney Figure 3a Figure 3b Disadvantages of the chimney Figure 4 1 The chimney is higher than the top of the roof a...

Страница 8: ...G Before the first firing wipe all painted surfaces with a clean and dry cloth in order to avoid burning of impurities on the stove and creation of unpleasant smells Start the fire in the stove by fol...

Страница 9: ...nvironmental pollution Increased ambient temperature can cause poor air circulation drafts in the chimney and in that case is recommended more frequent firing in smaller quantities Avoid using the coo...

Страница 10: ...chimney like loud roaring visible flames coming out of the chimney high ambient temperatures of surrounding walls and the characteristic smell of burning If there comes to the fire do the following Im...

Страница 11: ...The regulation of primary air is accomplished automatically by draft regulator Rathgeber Figure 5 Figure 5 When firing control button located on the frame of the stove turn to fully open flap in the...

Страница 12: ...be any single valve or any other fitting Closed expansion vessel is placed close to the boiler and has a short security line The volume of this vessel is determined by the capacity of the boiler wher...

Страница 13: ...system with built leaning pipe thermostat Pump 1 Intake valve Valve 2 Guide for filling and discharging the system exhaust valve 3 Distribution guide 4 Thermal exhaust valve 5 Drainage for overheated...

Страница 14: ...sional service in charge that guarantees the correct operation of the entire heating system In case of bad design of the system and possible shortcomings while installing it by the entity that did the...

Страница 15: ...y valve Figure 8 b Scheme of closed central heating system with built leaning pipe thermostat Pump 1 Intake valve Valve 2 The overflow pipe with a valve exhaust valve 3 Distribution guide Safety valve...

Страница 16: ...d after a long downtime Regular maintenance and control of the chimney will prevent the occurrence of fire and poor operation of the stove Malfunction Recommendations for its elimination Cleaning and...

Страница 17: ...heck a connection with a chimney Read carefully the instructions and apply advices how to provide secundary air GENERAL RECOMMANDATION If you have fullfield all the recommendations for installation op...

Страница 18: ...in effect Use only the recommended fuel It is forbiden burning an inorganic and organic materials plastics plywood textile oiled wood etc because the combustion releases carcinogenic materials and ot...

Страница 19: ...adequate exposure to rain snow etc due to chemical damage caused by exposure to inflammatory agents such as oil and oil products alcohol solvents paints due to natural disasters such as lightning floo...

Отзывы: