Page 8
www.kpa-solutions.com
4 OPERATING DETERMINATIONS
The CAMPLIFIER 90 add on amplifier module has been specially designed for the operation
mounted INSIDE of the Kemper Profiling Amplifier (KPA).
Any operation of the CAMPLIFIER 90 outside of the KPA is forbidden!
The Camplifier 90 is designed to be used as a stereo amplifier with two separate channels.
Both channel can power a 4 ohms speaker cabinet to 90Wrms.
Both channles can be run in
bridged mode
on a single speaker output with twice the output
power as a single stereo channel (180W). If the speaker is connected to the bridged mode out-
put, the speaker cabinets from the stereo speaker outputs must be disconnected.
The CAMPLIFIER 90 may be used to provide power amplification to speaker cabinets. The sig-
nal source must be the Kemper Profiling Amplifier (KPA).
Please note that the speaker systems connected to the Camplifier must provide a
minimal
imped-
ance of
4 ohms
and must be capable of handling at least
90W
rms.
Speaker system impedances bellow 8 ohms might damage the CAMPLIFIER 90!
Speaker systems with a specified max. power handling capacity of less than 180W might be
damaged by the CAMPLIFIERs high power output!
Bridged Mode :
In bridged mode, the seaker system connected to the Camplifier 290 must provide a
mini-
mal
impedance of
8 ohms
and must be capable of handling at least
90W
rms.
Speaker system impedances bellow 8 ohms might damage the CAMPLIFIER 290 if used in
brideged mode!
Speaker systems with a specified max. power handling capacity of less than 180W might
be damaged by the CAMPLIFIERs high power output!
This product is allowed to be operated with an alternating current of 30 V, 50 Hz and was de-
signed for indoor use only.
This device is designed for mobile use and for permanent installations.
By operating amplifying systems, you can produce excessive sound pressure levels that may
lead to permanent hearing loss. Please refer to the explanations under “Legal instructions”.