TECHNISONIC INDUSTRIES LIMITED
www.til.ca
TSR-4100 92-SC Installation & Operating Instructions
TiL 93RE125 Rev F
2-5
2.2.5
Remove/Replace Crystal Filter Board
REMOVAL
(1)
Remove dust cover of unit as described in Paragraph 2.2.1.
(2)
Remove and retain the four screws securing the crystal filter board assembly, P/N
923069-1 to the standoffs on the Frequency-Set Memory Board. Pull the crystal filter
board assembly straight up to avoid damaging the Frequency-Set Memory Board
connector pins.
REPLACEMENT
(1)
Align the pins on the bottom of the crystal filter board with their sockets on the Mother
Board. Push the crystal filter board straight down until it rests on the Mother Board
standoffs.
(2)
Secure the crystal filter board to the standoffs with the four mounting screws.
NOTE:
Make certain that the memory set board, module A5A1 is programmed to the same
operating frequency as the crystal filter board assembly. If no crystal filter board assembly
(option) is installed, jumper board assembly P/N 923074-1 must be installed.
2.3 CHANNEL
FREQUENCY
SELECTION
Early radios have their frequencies programmed by a diode matrix as
described in Section 2.3.3. For radio units shipped after July 2012 and
equipped with a USB port, please refer to Appendix A (TiL TDP-90
Programming Software User’s Guide for USB Programmable AM Series
Transceivers) - Document 11RE439.
2.3.1 Introduction
Before programming a new operating frequency, perform an operational check, as outlined in
Section 3. If there is any operational deficiency or equipment malfunction, return receiver to the
manufacturer. Before use it is necessary to pre-program the operating frequency.
2.3.2 Frequency
Range
The operating frequency may be programmed over the frequency range 117.975 MHz to 138.000
MHz with 25 kHz channel spacing.
2.3.3
Pre-programming Channel Frequency
FREQUENCY SELECTION MHz.
Refer to Table 2.1 Frequency Selection MHz. Using the OPERATING FREQUENCY (MHz)
column, find the desired frequency in MHz. Cross-refer to the JUMPER LOCATION column, and
install the jumper as required.
FREQUENCY SELECTION KHz
Refer to Table 2.2, Frequency Selection kHz. Using the OPERATING FREQUENCY kHz column,
find the portion of the desired frequency in kHz. Cross-refer to the JUMPER LOCATION column,
and install the jumpers in the locations as required.