TECHNISONIC INDUSTRIES LIMITED
www.til.ca
TLC-100 90-6R Installation & Operating Instructions
TiL 92RE130 Rev C
4-6
4.3
PREPARATION FOR USE
To prepare the transceiver for use:
(1)
Remove the microphone from its mounting bracket, and ensure that the microphone
connector is connected to the MIC/PTT connector of the transceiver.
(2)
Set the SQUELCH control in the fully counter-clockwise (CCW) position.
(3)
Set the VOLUME control in the 12 o'clock centre position.
(4)
Turn the SPG-010 Power Supply AC ON/OFF switch to the ON position.
(5)
Verify that the AC power ON indicator GREEN LED is ON.
(6)
Turn the SPG-010 Power Supply External Battery ON/OFF switch to the ON position if
external batteries are connected.
(7)
Set the POWER ON/OFF switch to position 1, toggle-up "ON" position.
(8)
Verify that the FUSE BLOWN red LED is OFF.
(9)
Verify that the POWER ON green LED is ON.
(10)
Set the CHANNEL switch to the desired operating channel 1 through 6.
(11)
Verify that the appropriate CHANNEL INDICATOR green LED is ON.
(12)
Proceed to operation in the transmit mode, paragraph 4.4, or operation in the receive
mode, paragraph 4.5, as appropriate.
4.3.1
Operation In The Transmit Mode
To operate in the transceiver transmit mode, proceed as follows:
(1)
Hold the microphone in one hand, with the upper edge of the microphone as close as
possible to the upper lip.
(2)
Depress and hold the PRESS-TO-TALK switch of the microphone during transmission
(3)
Ensure that the Tx ON yellow LED is ON.
(4)
Speak slowly and distinctly into the microphone using specified operating procedures
during transmission.
(5)
When message is ended, release the PRESS-TO-TALK switch of the microphone.
(6)
The transceiver is now operating in the receive mode.
(7)
Verify that the Tx ON yellow LED is OFF.