TECHNISONIC INDUSTRIES LIMITED
TDFM-9000 Installation Instructions
TiL 11RE442 Rev. D Issue 1
30
CONDITIONS
SECTION
CATEGORY
COMMENTS
Temperature and Altitude
4.0
A2, B1, C4, D1
Low Temperature – Survival
4.5.1
- 55 degrees C
Low Temperature – Short Time Operating
4.5.1
- 40 degrees C
Low Temperature – Operating
4.5.2
- 30 degrees C
High Temperature – Survival
4.5.3
+ 85 degrees C
High Temperature – Short Time Operating
4.5.3
+ 70 degrees C
High Temperature – Operating
4.5.4
+ 70 degrees C
In-Flight Loss of Cooling
4.5.5
Not applicable
Altitude
4.6.1
50,000 feet
Decompression
4.6.2
50,000 feet
Overpressure
4.6.3
- 15,000 feet
Temperature Variation
5.0
B
+/- 5 degrees C per minute
Humidity
6.0
A
Standard Humidity Environment
Operational Shock and Crash Safety
7.0
A
Standard Operational Shocks
Vibration
8.0
S
Sinusoidal Vibration – curve M
S
Random Vibration – curve B
U
Sine-On-Random Vibration – curve G
Explosive Atmosphere
9.0
X
Not tested
Waterproofness
10.0
X
Not tested
Fluids Susceptibility
11.0
X
Not tested
Sand and Dust
12.0
X
Not tested
Fungus
13.0
X
Not tested
Salt Fog Test
14.0
X
Not tested
Magnetic Effect
15.0
Z
Distance result was 0.21 meters
Power Input
16.0
B
See NOTE-2
Voltage Spike
17.0
B
Audio Frequency Susceptibility
18.0
B
Induced Signal Susceptibility
19.0
AC
Radio Frequency Susceptibility
20.0
T
See NOTE-1
Radio Frequency Emission
21.0
M
See NOTE-1
Lightning Induced Transient Susceptibility
22.0
X
Not tested
Lightning Direct Effects
23.0
X
Not tested
Icing
24.0
X
Not tested