5. Battery
5.1 Battery indication
The latest battery status is symbolised by a three-stage battery indicator.
indication of battery status
battery empty - you still can perform a few tests
(flashing symbol: no more measurements allowed)
Attention!
If the yellow LED lights up and the message „Lo Bat“ appears in the display, measurements are no longer
possible and the battery must be changed immediately.
The device works with a 9 V block battery IEC 6LR61 / 6LF22 / 6LP3146 (alkaline manganese).
5.2 Replacing the battery
Loosen the screw at the back of the instrument which secures the battery compartment lid, remove the lid.
Let the battery drop out of the battery compartment with its CAT IV protection cover and exchange it.
Therefore, snap the battery contacts onto the 9 V block battery and insert the battery together
with the CAT IV protection cover into the battery compartment. Put the lid back on the battery compartment
and screw it tight.
Regularly make sure that the battery of your device does not leak. In case it does, you have to replace the
electrolyte completely and to insert a new battery.
In case of a long storage period, remove the battery from the device.
Note!
Included in the scope of delivery is one battery. These battery is not to be re-charged. Attempting to
recharge it may cause risk to personal safety and damage to the equipment.
The battery may not to be opened. Depleted batteries must not be disposed with the domestic waste.
Please, return batteries at a local retailer or municipal recycling depot. Return is free of charge and required
by law.
6. Limited Warranty and Liability Limitation
By continuous quality checks and production controls, most modern electronics and high quality materials
we guarantee that the tester will be free from defects in material and workmanship for two years.
This warranty does not cover batteries, improper handling, not intended purpose, opening the housing,
improper storage or damages from accidents.
No other warranties such as fitness for a particular purpose will be given.
We are not liable for any indirect, incidental or consequential damages or losses arising from any cause or theory.
7. Repair
Repair is only allowed by the manufacturer or explicitly authorised repair shops.
In case of damages on the device or failure of the function test or for detailed inspection/calibration,
please contact:
or send the device and a description of failure back to the manufacturer.
8. Maintenance / Storage
The DSP-HW 2 is absolutely mainteinance-free. Nevertheless, observe the following information in order to
maintain safe operation:
•
Always keep the voltage tester dry and clean.
•
The housing can be cleaned with a cloth dampened with isopropyl (alcohol) or soapy water.