UP 300 Service Manual
Failure 06: Software shows that the nozzle
temperature or platform temperature is too high
Software reports nozzle high
temperature error
Software reports platform high
temperature error
Failure
Cause
Solution
Remark
⚫
Reports nozzle
high
temperature
when the
nozzle powers
on
⚫
Printing stops
and reports
nozzle high
temperature
error
⚫
Platform
automatically
heats up after
initialization
⚫
Software
reports
platform high
temperature
error when
loading model
➢
nozzle (nozzle
plate,
temperature
control
components,
etc.)
Turn off the power, remove and replace
the nozzle PCB board
Turn off the power, remove the nozzle,
and replace the integrated liquefied gas
Turn off the power and replace the
nozzle assembly
Remove and replace
the nozzle assembly
Remove and replace
the nozzle plate
Remove and replace
the integrated
liquefied gas
It is
recommende
d to replace
the nozzle
assembly
➢
nozzle is not
heated, fan
doesn’t run
when the
motor is
turned on
Turn off the power and replace the
nozzle PCB adapter board
Turn off the power and replace the
nozzle PCB board
➢
FFC-platform
heating wire
false
connection
Re-plug or replace the FFC-platform
heating cable
Replace FFC-platform
heating cable
➢
26P adapter
cable short
circuit
Re-plug or replace the 26P color cable
➢
Mainboard
damaged
Turn off the power and replace the
mainboard
Printing stops and reports nozzle
high temperature error