1
41
When the ideal platform
height is obtained, note
the value of the "Current
Height". This is the
platform height value.
Repeat steps 1 –6 for all
of the other eight positions
and note their platform
height values.
Platform Values at 9 calibration points (hypothetical):
1: 208
2: 208.5
3: 208.7
4: 208.6
5: 208.9
6: 209
7: 208.8
8: 208.9
9: 208.8
When you have obtained
the platform height values
for all nine positions, find
the lowest value among the
values.
In this example, the first
calibration point has the
lowest value and is thus
the highest point on the
platform. (The highest point
of the platform require
minimum amunt of travel to
reach the nozzle).
Type 208 in the text field
and click "Set" to set
nozzle height to 208.
5
6
7
8
The platform is too high. The nozzle
is pinning the Calibration Card onto
the platform. Lower the platform
slightly.
The height is just right.
Can feel some resistance when
moving paper.
The platform is too low. No
resistance is felt at all when
moving the paper. Raise the
platform slightly.
Содержание UP BOX+
Страница 1: ...1 USER MANUAL FOR UP BOX...
Страница 20: ...20 Click the dropdown menu to choose an available network 3 Choose your network from the drop down list...
Страница 47: ...47...