Platform calibration is the most important step for successful printing as it ensures part adhesion
on the first layer. Ideally, the distance between the nozzle and the platform is constant, but in
reality the distance varies at different positions due to many reasons (e.g. a slightly tilted platform),
which could cause warping on prints or even a complete print failure. Fortunately, UP BOX+
introduces the features like automatic platform leveling and automatic nozzle height detection,
which can make the calibration process finish quickly and easily.
In the Calibration section, click Auto Level to initiate auto
leveling. The leveling probe will be lowered and start to probe
nine positions on the platform. After probing the platform, the
leveling data will be updated and stored in the machine. The
leveling probe retracts automatically.
Nozzle height detection will be started automatically after auto
leveling process. The print head will move toward the nozzle
height detector. Eventually, the nozzle will touch and press the
thin metal sheet on the device to make the measurement.
Calibration Tips:
1. Perform calibration when the nozzle is not heated.
2. Remove residual plastic on the tip of the nozzle before calibration.
3. A print board should be in place on the platform before calibration.
4. Autoleveling and nozzle height detection can only be initiated when nozzle temperature is under 80 °C.
Automatic Platform Calibration
Auto leveling probe
retracted.
Auto leveling probe
lowered.
Nozzle Height
Dectector.