COMMANDER
FUNCTION
KEYS
©
Tieline Technology
- 18 -
August 2002
Function Key Options
Any of the following actions can be assigned to any Function key.
Function
Options
Function Description
01
Unused
02
Renegotiate up
COMMANDER will attempt to renegotiate a
higher bit rate for better audio quality.
The audio is muted for about 1 second
during this process.
03
Renegotiate down
Manually requests COMMANDER modems
to renegotiate a lower bit rate when current
line conditions no longer support the
prevailing bit rate. This is Indicated by
audible disturbances such as "popping"
noises or distortion. The audio is muted for
about 1 second during this process.
04
Retrain Current
COMMANDER modems communicate over
the line to establish the best possible
conditions for data transmission. The
modems “train” the line to compensate for
variations in frequency response and to
cancel out any echo that may be present.
This Function re equalizes the current line
whilst retaining the same bit rate.
The audio is muted for about 20 seconds
during this process.
05
Retrain up
Under some circumstances, particularly
when line conditions are subject to change,
it may be beneficial to manually request the
modems to "retrain" the line. This Function
manually retrains Up.
The audio is muted for about 20 seconds
during this process.
06
Retrain Down
This Function manually retrains Down.
(see above)
The audio is muted for about 20 seconds
during this process.
07
Retrain Auto
Automatically retrains (see above)
The audio is muted for about 20 seconds
during this process.
08
Reset Modem
Resets the Modem
09
Reset DSP
Restarts DSP operation
10
Lock & Unlock
Secure the COMMANDER and enter a lock
code - The default number to lock and
unlock COMMANDER is “1234”
11~16
Remote Relay Function 1-6
Controls the mechanical relays in a remote
TIELINE COMMANDER rack unit
Continued on next page…