71
IDU of No. 1 System
1_1
1_2
1_3
1_4
1_5
1_6
1_7
1_8
1_9
IDU numbering on the
wired controller
1 2 3 4 5 6 7 8 9
IDU of No. 2 System
2_1
2_2
2_3
2_4
2_5
2_6
2_7
IDU numbering on the
wired controller
10 11 12 13 14 15 16
IDU of No. 3 System
3_1
3_2
3_3
3_4
3_5
3_6
3_7
3_8
IDU numbering on the
wired controller
17 18 19 20 21 22 23 24
IDU of No. 4 System
4_1
4_2
4_3
4_4
4_5
4_6
IDU numbering on the
wired controller
25 26 27 28 29 30
4. Operation on a Single Unit for IDUs under Centralized Control
For example: To turn on No. 3 IDU and set temperature to 30°C, enable high fan speed,
swing and sleep functions, do as follows:
(1) Press “Separate Control” to display product number “NO--” at “Product No. Display
Area”;
(2) Press "Clock Up/Down" and the tens position of IDU No. flashes. Then, modify the
tens position of IDU No.;
(3) Press “Separate Control” to display the tens position of IDU No. at “Product No.
Display Area”; the ones position flashes;
(4) Press "Clock Up/Down" to modify the ones position of IDU No.;
(5) Press “Separate Control” to determine IDU No.; then “Product No. Display Area”
displays desired IDU No., while the other display areas display the desired IDU
status;
(6) Press “On/Off” to set IDU on/off status;
(7) Press "Temperature Up/Down" to set temperature;
(8) Press “Mode” to set IDU mode (Auto mode is unavailable);
(9) Press “Fan” to regulate fan speed; (note: set fan speed when the unit is on)
(10) Press “Swing”;
(11) Press
“Sleep”;
(12) Settings completed;
5. Centralized Operation for IDUs under Centralized Control:
For example: To turn on all the IDUs, and set temperature to 30°C, enable high fan speed,
swing, auxiliary electric heater and sleep functions, do as follows:
(1)
Press “Centralized Control”;
Содержание P70131000000
Страница 15: ...15 1 3 TIMS080 100 120 140 160AX 1 4 TIMS180 200 220AX ...
Страница 16: ...16 1 5 TIMS080 100 120AST Copper silencer 1 6 TIMS140 160 180AST Copper silencer Refrigerant cooling loop ...
Страница 38: ...38 Heating mode ...
Страница 46: ...46 4 1 Remote controller instructions Functions ...
Страница 65: ...65 Then the following screen appears Click IDU Data set IDU operating data click Confirm ...
Страница 66: ...66 3 Centralized Control 3 1 Methods of installing TIMS centralized wired controller ...
Страница 103: ...103 Troubleshooting Remarks Figure 1 Thermal conductive silicon grease is applied unevenly ...
Страница 108: ...108 Troubleshooting Measure the in between pressure DC Body Electrical wiring drawing ...
Страница 131: ...131 2 Low voltage is too low ...
Страница 149: ...149 ...
Страница 150: ...150 2 22 Compressor startup current is too large Fault code E007 E03 4 ...
Страница 151: ...151 2 23 Trip ...
Страница 162: ...162 2 2 IDU TMDN AB AC TMDH A TMDF A TMDN AB EXV 220V 50Hz Water level On Off ...