21
A – The radio type can be either Simplex (RT5022) or Duplex (RT5020 – with built in duplex
filter).
B – The ATIS killer is used in Inland Waters channel mode. If ATIS killer is ON the ATIS
code will be muted in the speakers. If the ATIS killer is set to OFF, the ATIS code will be
heard and can be used for decoding purposes in external equipment.
C – The settings that are controlled with these three parameters are related to scanning only
(default settings are displayed in the Figure).
•
Scan Hang Time
. The time the scanning algorithm will stay on a channel (different
from the priority channel) after the carrier has disappeared. Range: 30-5,000 (ms).
•
Scan Pause Time
. The time the scanning algorithm remains on a channel (different
from the priority channel) with an active signal, before moving to the next channel in
the scan table. Range: 1,000-20,000 (ms).
•
Priority Hang time. The time the scanning algorithm will stay on the priority channel
after the carrier has disappeared. Range: 30-5,000 (ms).
Items A, B and C are updated when entered by clicking the Configure button.
D – The unit serial number is entered and saved clicking the Save Serial no. button.
Note: The serial number is only programmable once, and must be programmed to the
same number as labelled on the radio. The serial number will eventually be used to enable
add-on software features in the future.
If the serial number has been programmed the field turns into a read-only field.
E – If, for any reason, a VHF radio needs clean-up in the configuration area, a click on the
button in the Factory reset field followed by acceptance of the erasure will erase all
configuration data to the factory default values, except for the serial number that cannot
be erased. That is:
•
DSC parameters, including MMSI number
•
System parameters
•
Channel settings, including configured weather channels
•
Contact list
•
Logs and statistics
4.3
Printer Configuration on an LB5007 LAN
Box
The RT5022/RT5020 supports a printer to be connected for printing of DSC logs. Please
refer to the Sailor VHF 5000 series workshop manual for installation details.
The printer configuration procedure is presented in this manual because the internal software
and hardware of the SB5006 and LB5007 is identical. This means you should connect the
service computer into the LB5007 Ethernet connection while configuring the printer server.
Bring up the printer configuration page clicking the Printer Setting link on the index page.