TROUBLE SHOOTING GUIDE

 

PROBLEM 

POSSIBLE CAUSE 

REMEDY 

COMMENT 

MACHINE WILL 

NOT START 

Power not plugged in and switched 
on 

Plug into appropriate outlet and 
switch on at the wall, then at the 
machine 

If Electrical 

  

No Fuel 

Check Fuel. Re-fill fuel tank. 

If Petrol or Diesel 

  

No Fuel 

Open fuel tank ball valve or fuel 
solenoid tap 

If Petrol or Diesel 

  

No or low water supply 

Check water supply 

If fitted with break tank and 
auto shut-down 

  

Float switch sticking 

Check float switch in water tank 

If fitted 

  

Emergency-Stop engaged 

Disengage 

If fitted 

  

Battery Isolator switch engaged 

Disengage 

If fitted 

  

Starter Isolator Switch engaged 

Disengage 

If fitted 

  

Pump oil level too low 

Top up with SAE15W40 or SAE30 

If fitted with low level 
switch 

  

Pump oil over temp 

Allow to cool down 

If fitted with oil over temp 
switch 

  

Boiler over temp 

Allow to cool down 

If fitted with over temp 
switch 

  

Timed by-pass shutdown 

First switch off and then on again 

Some electrical units 

Check if there is water in the suction 
line 

  

Check if the gun is open 

  

Check if nozzle is not blocked 

  

THE PUMP 

RUNS BUT DOES 

NOT PRODUCE 

NOISE OR 

PRESSURE 

The pump is not primed and is 

running dry 

Check that the valves are not 
blocked 

  

Cavitation or air in the system 

Check suction hose. Increase 
diameter size for bigger supply 

  

Damaged ceramic plunger 

Replace Plunger 

  

SHORT 

PLUNGER SEAL 

LIFE 

Excessive pressure and/or temp in 
the pumped water 

Check the temperature and pressure 
of inlet water 

  

Problems with pump-motor 
connection 

Check status of drive shaft keys, 
flexible coupling or pulley 

  

The oil has not been changed 
regularly 

Change oil as instructed in the 
maintenance schedule 

  

SHORT BEARING 

LIFE 

Excessive pressure of pumped 
water 

Check the pressure 

  

Sucking air 

Check Suction for Air Leaks 

  

Valves Sticking 

Remove – Clean – Replace 

Check Water Quality 

Seat in Unloader Valve Worn/ By-
Passing Water 

Remove – Fit BPV Service Kit Or 
Exchange Valve 

Probably Indicate Service 
Required 

HP Jet Wrong Size – Worn Out 

Check – Replace 

  

Worn Piston Plunger H.P. Seals  

Check – Replace 

Check Pistons for Cracks 

Pressure control valve not set right 

Calibrate valve. Check seal seat 

  

Low speed/rotation 

Check motor revs and drive 

  

MACHINE 

RUNNING OKAY, 

BUT NOT 

REACHING 

SPECIFIED 

PRESSURE 

Insufficient Water Supply 

Check Available Water Supply. Clean 
Filters in Suction Line. Increase 
supply hose size 

  

Valves Worn/Sticking 

Remove – Clean – Replace 

Check Water Quality 

Blockages/Debris in By-Pass Valve 

Remove – Clean – Replace 

Check Filters for damage 

Pump Sucking Air 

Seal Suction 

  

Jet too small 

Check correct size and replace 

  

FLUCTUATING 

PRESSURE 

Worn Piston HP Seals 

Remove – Clean – Replace 

Service Required 

Содержание E15i-43C

Страница 1: ...4 Operating Tips Shutting down Regular Checks 5 Maintenance Schedule 6 7 Trouble Shooting Guide 8 What can cause expensive damage to your machine 9 WARNINGS SAFETY INSTRUCTIONS 10 MEDIC ALERT Informa...

Страница 2: ...18 lpm Set up de rated pressure flow 1100 psi 11 lpm 1100 psi 11 lpm 3000 psi 18 lpm 4000 psi possible 3000 psi 18 lpm 4000 psi possible Nozzle size at set up pressure 15060 15060 15060 15060 Pump Sp...

Страница 3: ...t pump flow rate litres per minute Turn on the water supply open tap fully Water will fill the break tank if fitted Unroll the hose fully ensuring there are no kinks in it Trigger gun to expel any air...

Страница 4: ...operating pressure If pressure drops over time it may indicate general wear and tear and a service is recommended Air Leaks Especially in suction to pump hoses Repair immediately if found Check for cu...

Страница 5: ...t Tag electrical equipment as Specified by Law As required by law 12 CONTROL PANEL Have an Authorised Electrician Fully Function Test Repair or Replace all Electrical Components As required or annuall...

Страница 6: ...system Check suction hose Increase diameter size for bigger supply Damaged ceramic plunger Replace Plunger SHORT PLUNGER SEAL LIFE Excessive pressure and or temp in the pumped water Check the tempera...

Страница 7: ...ton Check Replace OIL IN PUMP EMULSIFIED CONTAMINATED BY WATER water in the oil Water Blasted into Pump via Breather Cap during Cleaning Exercise Care H P Piston Seals Worn or Check and Replace Seal P...

Страница 8: ...ost through by pass valve and only small increase in pressure is achieved doing this Lost of waster horse power When orifice is reduced the PSI will rise and then by pass valve will dump thinking the...

Страница 9: ...enetration would be detrimental NEVER WATER BLAST fragile items surfaces that may be damaged by high velocity water Always carefully test on a small area first ALWAYS WEAR PROTECTIVE GEAR PPE i e Head...

Страница 10: ...pecial note of any chemicals that were used and the quality of the water MEDIC ALERT INFORMATION ALWAYS ENSURE MACHINE IS FITTED WITH A REMOVEABLE MEDICAL ALERT WARNING TAG AND TAKE THIS TO A MEDICAL...

Страница 11: ...able loss or damage You are also entitled to have the goods repaired or replaced if goods fail to be of acceptable quality and the failure does not amount to a major failure The benefits to the consum...

Страница 12: ...y period THIS WARRANTY WILL NOT APPLY TO Any part component that has been subject to misuse negligence accidental damage improper or inadequate maintenance or improper storage Any part that has been s...

Страница 13: ...n the required flow of the pressure pump specification and suitable power supply outlet for electrical units where applicable 8 No responsibility will be taken for late delivery day due to unforeseen...

Страница 14: ...3 6 6 10 8 GPM 0 3000 PSI Features all stainless and brass internal parts New design reduces sensitivity to entrapped air No external moving parts or springs Unique barb and flow balance design provid...

Страница 15: ...3 15 16 22 24 25 28 29 INSTALLATION Select an unloader appropriate for the pressure and flow of your system see specification chart This unloading valve is a flow through design and should be mounted...

Страница 16: ......

Страница 17: ......

Страница 18: ...lvola 6 23 0900 30 Valve spring Molla valvola 6 24 0604 10 Valve cage Gabbia valvola 6 25 1801 12 Screw Vite M6x16 12 26 0203 18 Bearing cover Coperchio cuscinetto 2 27 0205 02 Bearing seal Cappellott...

Страница 19: ...istone 18 1 2600 43 Complete seal Packing 18 mm 2600 43 Pacco completo Guarnizioni pistone 18 3 2614 05 Plunger 18 mm 2614 05 Pistone 18 3 2600 28 Complete Valve 2600 28 Valvola completa 1 2608 26 Plu...

Страница 20: ...0 0 0 03 3 3 36 6 6 6 0 0 0 0 0 0 0 00 0 0 00 0 0 0 2 2 2 2 8 8 8 8 5 5 5 50 0 0 0 2 2 2 2 XLT3816S 160 2320 38 46 10 12 1000 1200 15 9 19 0 11 7 14 0 XLT5015 150 2175 50 60 13 2 15 8 1450 1740 18 8 2...

Страница 21: ...LT3816S XLT1830 XLT2230 XLT2530 XLT2520 XLT2730 XLT3025 XLT3020 XLT3325 XLT3517 XLT4017 XLT4014 XLT4317 XLT5015 XLT5415 23 24 25 26 27 28 29 30 27 31 26 32 33 24 23 34 35 36 37 38 39 40 41 42 43 44 45...

Страница 22: ...3 2601 14 Complete seal Packing 25 mm 3 2601 16 Complete seal Packing 28 mm 3 2601 30 Plunger 20 mm 3 2601 29 Plunger 22 mm 3 2601 17 Plunger 25 mm 3 2601 18 Plunger 28 mm 3 2600 10 Complete Valve 6 2...

Страница 23: ...65 U seal dia 28 mm 3 8 1601 33 Brass plug G3 4 1 9 0603 11 Copper washer 3 4 1 1602 39 Manifold housing 28 25 1 1602 40 Manifold housing 22 20 1 0601 66 O Ring 2 62x25 7 6 0601 18 O Ring 2 62x21 89...

Страница 24: ...Bonded seal 3 1200 32 Plunger 20 mm 3 1200 34 Plunger 22 mm 3 1200 33 Plunger 25 mm 3 1200 30 Plunger 28 mm 3 37 1400 57 Copper spacer 3 38 0003 32 Plunger rod 3 39 1502 07 Connecting rod pin 3 40 010...

Страница 25: ...1 1 2 2 3 3 4 4 5 5 6 6 A A B B C C D D E3R 22C Circuit Diagram A Ferero 3 11 2011 Designed by Checked by Approved by Date 1 1 Edition Sheet Date M...

Страница 26: ...2 2 3 3 4 4 5 5 6 6 A A B B C C D D E15I Circuit Diagram A Ferero D Cover 22 11 2011 Designed by Checked by Approved by Date 1 1 Edition Sheet Date L1 L2 L3 30 VA 415 240 2A C1 EOL M EOL STOP START C1...

Страница 27: ...12 Designed by Checked by Approved by Date 1 1 Edition Sheet Date 1 2 3 415V 24V 2A EOL R1 STOP START C1 C1 R1 4 5 C1 EOL M 1 2 3 Supply 4 5 Water shutdown Instant 6 7 Timed shutdown set to OP T1 T1 6...

Отзывы: