FALUN Aqua
15. Space Heating Capacity
For rooms with insulation non-conform with calorific insulation regulations space heating capacity should be determined pursuant to
DIN 18 893 for nominal heating capacity of 8 kW:
in favourable heating conditions
- 190 m
3
in poor heating conditions
- 145 m
3
in unfavourable heating conditions
- 98 m
3
For occasional heating – interrupted for more than 8 hours – space heating capacity is reduced by 25%.
16. Technical Data
Capacity:
8 kW
Heat flow at the side of water:
4 kW
Exchanger volume:
10,5 l
Exchanger outlet (input – output):
G1” (external thread)
Maximum allowed operating overpressure of water:
2 bar
Maximum allowed operating temperature of water:
90°C
Weight: FALUN Aqua = 111 kg, FALUN ceramic Aqua =136 kg
Upper flue gas outlet: 150 mm
Data for chimney properties calculation (at nominal heating capacity):
Fuel
Wood logs
Lignite briquettes
Flue gas flow [gs
-1
]
8,8
6,3
Average temperature of flue after draught shaft [°C]
304
271
Min. draught at nominal heating capacity [Pa]
12
12
Guarantee
Shall any failure, malfunction, or surface defect occur on your heater within the guarantee period do never repair it by yourself. After-
sale service can be done only by the manufacturer or distributor.
We guarantee the quality, function, and construction of the cooker for 2 years from the day of purchase: defects definitely occurred as a
consequence of manufacturing defect will be remedied within short time at our cost under the condition that the heater:
- has been operated in conformity with operating instruction,
- has been connected to the chimney in conformity with applicable standards,
- has not been damaged mechanically by force,
- has not been subject to modifications, repairs and incompetent handling
When making a complaint give your exact address and circumstances when the dysfunction occurred. We will deal with the complaint
if you deliver the warranty certificate with the date of purchase and the sales point stamp along with the complaint.
Ask for legible warranty certificate at purchase. Our company will decide on method and place of reparation to be carried out.
Upon purchase, check for integrity of the firing door glass. This is under guarantee for 15 days after the purchase.
It is unacceptable to operate the appliance at extreme conditions, which means:
-
fuel quantity exceeds the recommended quantity,
-
air supply exceeds the recommended quantity,
-
unacceptable fuel types are used.
Heat overcharge shows in the following ways:
-
fireplace ceiling deflection,
-
firing door damage
-
grille has burnt over,
-
refractory-bricks have cracked,
-
change of colour tone of the heater surface
The complaint will not be accepted by the manufacturer if the appliance has not been operated correctly.
Exchange of the product or making the purchase contract void is subject to applicable dispositions of the Civil Code and the
Complaints Order.
SUPPLEMENTARY CLAUSE
The manufacturer recommends disposing the different parts of the packaging as follows:
- take the steel stripe and the cardboard to a collecting point,
- wooden parts can be burnt.
Once the service life of the product has expired the manufacturer recommends disposing it at a collection point, and the refractory
blocks and ceramic parts at a waste deposit.