4
Installation
2.3 Preparation
The compressor is shipped without oil. Before use you must fill the motor to the
correct level as follows.
1) Remove the oil filler plug from the motor housing (see Fig. 2.1).
Warning
. Although the oil used in the compressor does not contain any hazardous
substances, care should be taken to avoid contact with the skin.
Cautions
.
•
During item (2), use only ISO 32 Fully Synthetic Compressor Oil.
•
Do not overfill the reservoir. Damage to the oil seals could occur if the level indicated on
the sight glass is exceeded.
2) Fill the housing with oil until the level is aligned with the mark on the sight glass
(approx 500cc).
3) Refit the oil filler plug, taking care not to overtighten.
Fig. 2.1 Rear view
Oil Filler Plug
Oil Level Sight Glass
Control Box
Capacitor
Pressure Relief Valve
Air Filter Housing