10
Troubleshooting
Compressor starts when no air Is tapped
1) Air leaks. Can be due to a bad seal/connection of any pipe. Check all pipe
connections.
Compressor starts and stops more frequently than usual
1) Large amount of condensate in air tank. Drain air tank.
2) Air leaks. Can be due to a bad seal/connection of any pipe. Check all pipe
connections.
Compressor does not switch on when pressure is under the minimum level
and/or does not switch off at maximum pressure
1) Replace pressure switch.
Compressor gets very hot and/or uses a lot of oil
1) Oil level incorrect. Replenish oil to correct level.
2) Wrong oil used in compressor. Drain and refill with correct oil.
3) Air Leak. Can be due to a bad seal/connection of any pipe. Check all pipe
connections.
4) Air filter clogged. Clean or replace the filter.
5) Outside air temperature too high. Ensure adequate ventilation.
Содержание PTA011
Страница 1: ...AIR COMPRESSOR Model Number PTA011 and PTA511...
Страница 14: ...12 Intentionally Blank...