![THORLABS ECL1525-PM Скачать руководство пользователя страница 30](http://html.mh-extra.com/html/thorlabs/ecl1525-pm/ecl1525-pm_operation-manual_1110697030.webp)
6.3
ECL1525 specific commands
ECL1525M-PM/SM / page 26
6.3 ECL1525 specific commands
6.3.1 Arbitrary Wavelength Set (ArbWave)
Purpose: ArbWave sets an arbitrary wavelength in the wavelength range [
λ
min,
λ
max
].
Synopsis
Register
name
Register
number
Read/
Write
Datatype Response
Generated
Can be
pending?
Volatile?
Access?
Default contents
R Unsigned
short
5ms no Non-
volatile
0x0000
ArbWave 0x80
W Unsigned
short
5ms yes
Lockable
1
Returns
Same as the Channel (0x30) command.
Detailed description
The frequency is defined as:
Freq(GHz)=0x35*10
3
+0x36*10
-1
+(0x30-1)*(0x34/10)-(0x34/20)+(0x80*0x34/2500)
Bits 7:0
8 bit wavelength
6.3.2 Tuning Range Set (Tstop)
Purpose: Tstop sets the tuning range stop channel. Synopsis
Register
name
Register
number
Read/
Write
Datatype
Response
Generated
Can be
pending?
Volatile?
Access?
Default
contents
R Unsigned
short
5ms no
Non-
volatile
0x0001
TStop 0x81
W Unsigned
short
5ms no
Lockable
1
Returns
Same as the Channel (0x30) command.
Detailed description
The tuning range is defined as:
Содержание ECL1525-PM
Страница 1: ...Operation Manual Digitally Controlled Continously Tunable Laser ECL ECL1525M PM SM 2005 ...
Страница 2: ...Version 1 0 Date 16 Feb 05 Copyright 2005 Thorlabs Sweden AB Sweden ...
Страница 6: ...1 1 Safety ECL1525M PM SM page 2 ...
Страница 11: ...2 1 Size ECL1525M PM SM page 7 2 Mechanical Interface 2 1 Size Optical Module ...
Страница 12: ...2 1 Size ECL1525M PM SM page 8 Electronic Control Board ...
Страница 14: ......
Страница 38: ......