Trouble shooting
22
BURNER TROUBLE SHOOTING
COMBINATION VALVE REMOVAL:
1. Shutdown the fryer. Follow the complete
shutdown procedure.
2. Shut-off the main isolation valve and follow
the lock-out/tag-out procedure.
3. Let the fryer cool down for a few minutes
before starting your work.
4. Remove the sensor probe. Follow the sensor
probe removal procedure.
5. Disconnect the thermocouple, pilot tube and
High Temp. Protector wires from the
combination valve.
6. Remove the two mounting screws of the
combination valve.
7. Disconnect the inlet pipe adaptor from the
combination valve.
8. Disconnect the outlet pipe adaptor from the
combination valve.
9. Remove the sensor probe from the fryer pot
thru the bottom.
10. Make sure to thoroughly dry the burner
before re-installing.
Remove the sensor probe of
combination valve
Remove the pilot tube, thermocouple
and High Temperature Protector wire
from the combination valve.
Remove the two mounting screws of
the combination valve
PILOT
TUBE
THERMOCOUPLE
HIGH TEMPERATURE
PROTECTOR WIRES
SENSOR PROBE
OF COMBINATION
VALVE
SENSOR PROBE
OF HIGH TEMP.
PROTECTOR
Disconnect the inlet and outlet pipe
adaptors from the combination valve
INLET PIPE
ADAPTOR
OUTLET PIPE
ADAPTOR
Remove the sensor probe thru the
bottom of the fryer
Remove the combination valve
HIGH TEMP.
PROTECTOR
PROBE SEAL
COMBINATION
VALVE PROBE
SEAL