Trouble shooting
20
PILOT TROUBLE SHOOTING
Disconnect the pilot tube from the FDS
FLAME DEVICE SYSTEM (FDS) REMOVAL:
1. Shutdown the fryer. Follow the complete
shutdown procedure.
2. Shut-off the main isolation valve and follow
the lock-out/tag-out procedure.
3. Let the fryer cool down for a few minutes
before starting your work.
4. Disconnect the pilot tube from the ODS
injector. Use 12mm spanner.
5. Disconnect the thermocouple from the
combination valve. Use 9mm spanner
6. Pull-out to disconnect the igniter wire from
the piezo igniter.
7. Remove the FDS mounting screws.
8. Remove the Flame Device System and replace
if necessary.
9. Make sure to check for gas leak, using soap &
water, after part installation.
Disconnect thermocouple from the
combination valve
Disconnect the igniter wire from the
piezo igniter
Remove the mounting screw of the
FDS