![THOMSON VK231PS Скачать руководство пользователя страница 61](http://html1.mh-extra.com/html/thomson/vk231ps/vk231ps_technical-manual_1109803061.webp)
57
MAINS POWER CUT
In the event of a mains power cut, the video recorder continues to power the clock for
30 minutes.
When a mains power cut occurs, Transistors TP082 and TP086 become saturated, and
impose a low level on the collector of TP086. This signal is transmitted to Pin 49 of servo
control microcontroller IT001 (POWER GOOD or microcontroller halt).
0.1-F Battery CT053 powers VCC1 Pin 14 and servo control microcontroller IT001 VCC2
Pin 64.
During this phase, the microcontroller powers the clock function stage only, using its 32kHz
oscillator.
The 16MHz oscillator is stopped.