KayakDD Installation Planning Guide
13
KayakDD-1 Installation
KayakDD-1 Cabling
Control Cabling
Figure 8. KayakDD-1 Standard Control Cabling
The KayakDD-1 system uses Ethernet, serial, parallel, and USB connec-
tions. Tally and GPI/O control are also available. A simple KayakDD-1
system consisting of a Control Panel and Video Processor frame uses point-
to-point connections and does not require connection to an external
Ethernet Local Area Network (LAN).
Note
The point to point connection between the Control Panel and Video Processor
frame require swapped Transmit (TX) and Receive (RX) pairs. This is nor-
mally achieved with a crossover LAN cable or an Uplink port on a switch or
hub. The LAN cable supplied with the KayakDD system is a crossover cable.
A KayakDD system requires a LAN when components besides a Control
Panel and Video Processor frame are connected, or when external network
access to a file system is desired. An appropriately sized Ethernet switch
will be required. An existing facility Ethernet switch (not hub) can support
KayakDD if an adequate number of ports are available. Keep your facility
network and technical network separate in order to avoid network traffic
negatively affecting KayakDD system operation. An Ethernet hub or
switch will be necessary if cable runs exceed allowable maximums.
N4067
N4067
GPI/O - Tally
GPI/O - Tally
LAN
LAN
RS 485
RS 485
INPUT
INPUT
REFERENCE
REFERENCE
AUX
AUX
M/E
M/E
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) This device may not cause harmful interference, and
(1) This device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired operation.
(2) this device must accept any interference received, including interference that may cause undesired operation.
AC POWER IN
AC POWER IN
100 - 240 V
100 - 240 V
max. 4A
max. 4A
50/60 Hz
50/60 Hz
DC POWER
DC POWER
IN
IN
OUT
OUT
J2
J2
J3
J3
J 4
J 4
J 5
J 5
J 6
J 6
J 7
J 7
J 8
J 8
PGM-A
PGM-A
CLEAN
CLEAN
PVW-A
PVW-A
CLEAN-PVW
CLEAN-PVW
AUX 1
AUX 1
AUX 2
AUX 2
AUX 3
AUX 3
AUX 4
AUX 4
AUX 5
AUX 5
AUX 6
AUX 6
AUX 7
AUX 7
AUX 8
AUX 8
AUX 9
AUX 9
AUX 10
AUX 10
J 9
J 9
J 10
J 10
J 11
J 11
J 12
J 12
J 13
J 13
J 14
J 14
J 15
J 15
J 16
J 16
J 17
J 17
J 18
J 18
Port 1
Port 1
Port 2
Port 2
Port 3
Port 3
Port 4
Port 4
Port 5
Port 5
Port 6
Port 6
J 19
J 19
J 20
J 20
J 21
J 21
J 22
J 22
J 24
J 24
J 23
J 23
J 25
J 25
IN 1
IN 1
IN 2
IN 2
IN 3
IN 3
J 26
J 26
J 27
J 27
J 28
J 28
J 29
J 29
J 30
J 30
J 31
J 31
J 32
J 32
J 33
J 33
J 34
J 34
J 35
J 35
J 36
J 36
J 37
J 37
J 38
J 38
J 39
J 39
J 40
J 40
IN 4
IN 4
IN 5
IN 5
IN 6
IN 6
IN 7
IN 7
IN 8
IN 8
IN 9
IN 9
IN 10
IN 10
IN 11
IN 11
IN 12
IN 12
IN 13
IN 13
IN 14
IN 14
IN 15
IN 15
IN 16
IN 16
J 41
J 41
J 42
J 42
ANALOG
ANALOG
J 44
J 44
J 43
J 43
grass valley
grass valley
48V / 5A max.
48V / 5A max.
KAYAK
KAYAK
DD
DD
1 M/E DIGITAL SWITCHER
1 M/E DIGITAL SWITCHER
48V / 1,6A
48V / 1,6A
R
3S13
3S13
Prof. Vid. Equipm.
Prof. Vid. Equipm.
Listed
Listed
Caution:
Caution:
For continued protection against risk
For continued protection against risk
of fire, repplace only with same type and rating of fuse.
of fire, repplace only with same type and rating of fuse.
2*T6,3A /H
2*T6,3A /H
250V
250V
J1
J1
+
-
+
-
8324_07_r0
Mouse
Note:
Keyboard and Mouse not
manditory and not supplied.
CAT5 Crossover Cable
Suplied DC Interconnect Cable
Keyboard
Control Panel
Video Processor Frame
48V DC
Power Supply
48V DC
Power Supply
(Redudancy)
110-240V AC
Power Supply
alternatively