Pin Assignments

 

Frame DC Power In

Note

Pins 2 and 5 must be connected in the plug of the external power supply unit.

Frame DC Power Out

Socket

Pin

Signal

 

A1

48 V (+)

A2

48 V (-)

1

Ground 

2

Return Sense *

3

+ 7 V (RAM Rec)

4

-

5

48V Return *

Table 2.  

Socket

Pin

Signal

 

A1

48 V (+)

A2

48 V (-)

1

-

2

-

3

-

4

-

5

-

Pin A2

Pin 2

Pin 1

Pin A1

Pin 5

Pin 3

D-Sub Male

Pin A1

Pin 1

Pin 2

Pin A2

Pin 3

Pin 5

D-Sub Female

Содержание GRASS VALLEY KayakDD Series

Страница 1: ...KayakDD DIGITAL PRODUCTION SWITCHER Installation Planning Guide 071832400 MAY 2004 ...

Страница 2: ...ase Solutions to problems and troubleshooting efforts can be found by searching our Frequently Asked Questions FAQ database Software Downloads Software updates drivers and patches can be down loaded Region Voice Fax Address Web Site North America 800 547 8949 Support 530 478 4148 Sales 530 478 3347 Support 530 478 3181 Grass Valley P O Box 599000 Nevada City CA 95959 7900 USA www thomsongrassvalle...

Страница 3: ...s 10 Fastening to Table Top 10 KayakDD 1 Video Processor Frame Installation 11 Measurements 11 Rack Mounting 12 KayakDD 1 Cabling 13 Control Cabling 13 Video Cabling 14 KayakDD 2 Installation 15 Kayak DD 2 System Components 15 Kayak DD 2 Control Panel Installation 16 Measurements 16 Panel Mounting Options 17 Table Top 17 Surface Mount Cut Out Dimensions 17 Fastening to Table Top 18 Frame 19 Measur...

Страница 4: ...4 KayakDD Installation Planning Guide Contents ...

Страница 5: ...product Two basic models are available the KayakDD 1 one Mix Effects switcher and the KayakDD 2 two M E switcher Features Switchable between 525 line and 625 line formats Fully digital 10 bit 4 2 2 inputs outputs and video processing Compact lightweight frame KayakDD 1 frame is 2 RU high the KayakDD 2 frame is 3 RU high Low power consumption Intuitive menu with touch screen Number of inputs 16 for...

Страница 6: ...toring support via NetCentral software KDD PSU redundant power supply unit Supported Control Protocols VTRs BVW 75 Servers Louth VDCP Odetics BVS Routers Routing Control Systems Trinix Venus Triton and third party routers Jupiter and Encore future router control sys tems Control Systems Grass Valley Andromeda and third party systems Grass Valley under monitor displays Grass Valley external auxilia...

Страница 7: ... Installation KayakDD 1 System Components A KayakDD 1 Production Switcher system consists of a control panel with integrated menu display color TFT with touch screen and a 2 RU Video Processor Frame Figure 1 KayakDD 1 Control Panel Figure 2 KayakDD 1 Video Processor Frame ...

Страница 8: ...ol Panel Installation Measurements Figure 3 Kayak DD 1 Control Panel Measurements 1 of 2 8324_00_01_r0 16 46 in 418 mm 15 66 in 397 74 mm 0 39 in 10 mm 1 31 in 33 33 mm 0 60 in 15 3 mm 0 40 in 10 26 mm 2 55 in 64 75 mm 3 19 in 80 95 mm 10 23 in 259 88 mm 5 69 in 144 53 mm 2 0 7 ...

Страница 9: ...Installation Planning Guide 9 KayakDD 1 Installation Figure 4 Kayak DD 1 Control Panel Measurements 2 of 2 8324_02_r0 17 64 in 448 mm 17 64 in 448 mm 16 85 in 428 mm 15 46 in 418 mm 0 39 in 10 mm 0 39 in 10 mm ...

Страница 10: ... mounting CAUTION At least 2 inches 50mm of open space at the rear of the panel below the mounting surface is required for proper cable clearance and air flow Fastening to Table Top Four M4 thread drillings are available for fastening the panel to a table top Figure 5 Figure 5 KayakDD 1 Panel Mounting Drillings Four M4 thread drillings for panel fastening 8324_03_r0 10 55 in 268 mm 2 95 in 75 mm 1...

Страница 11: ...on KayakDD 1 Video Processor Frame Installation Measurements Figure 6 KayakDD 1 Frame Dimensions Air Flow 19 0 in 482 mm 17 48 in 444 05 mm 16 67 in 423 4 mm 15 94 in 404 9 mm 3 44 in 87 5 mm 3 0 in 76 2 mm 0 18 in 4 5 mm 8324_04_r0 18 3 in 465 mm 3 5 in 89 mm ...

Страница 12: ... 7 KayakDD 1 Rack Mounting CAUTION Mounting using only the front rack angles is permitted for fixed installations Additional support like slide rails is required for mobile applications flight case OB van Slide rails Recommended for mobil applications Not part of delivery 8324_05_r0 ...

Страница 13: ... harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation 2 this device must accept any interference received including interference that may cause undesired operation AC POWER IN AC POWER IN 100 240 V 100 240 V max 4A max 4A 50 60 Hz 50 60 Hz DC POWER DC POWER IN IN OUT OUT J2 J2 J3 J3 J 4 J 4 J 5 J 5 J 6 J 6 J 7 J 7 J ...

Страница 14: ...connector only Any KayakDD video source can be routed to any Aux bus output 1 through 10 Reference Input The looping reference input accepts analog 525 or 625 composite video Burst is not required but typically facility reference color black is used KayakDD can auto sense whether the reference is 525 or 625 and can change the internal standard accordingly Table 1 Ethernet Specifications Cables Typ...

Страница 15: ...Installation Kayak DD 2 System Components A KayakDD 2 Production Switcher system consists of a control panel with integrated menu display color TFT with touch screen and a 3 RU Video Processor Frame Figure 9 KayakDD 2 Control Panel Figure 10 KayakDD 2 Video Processor Frame ...

Страница 16: ...trol Panel Installation Measurements Figure 11 Kayak DD 2 Control Panel Measurements 1of 2 8324_08_r0 16 46 in 418 mm 15 66 in 397 74 mm 0 39 in 10 mm 1 31 in 33 33 mm 0 60 in 15 3 mm 0 40 in 10 26 mm 2 55 in 64 75 mm 3 19 in 80 95 mm 10 23 in 259 88 mm 5 69 in 144 53 mm 2 0 7 ...

Страница 17: ...Mounting Options Table Top The panel can be placed on a table Gummed feet prevent accidental move ment of the panel Surface Mount Cut Out Dimensions Cut a 31 2 in 791mm x 15 75 in 400 mm hole in table top for surface mounting 8324_09_r0 31 9 in 809 mm 31 9 in 809 mm 31 1 in 789 mm 16 5 in 418 mm 0 39 in 10 mm 0 39 in 10 mm ...

Страница 18: ... mounting surface is required for proper cable clearance and air flow Fastening to Table Top Four M4 thread drillings are available for fastening the panel to a table top Figure 13 Figure 13 KayakDD 2 Panel Mounting Drillings 10 55 in 268 mm 2 95 in 75 mm 31 46 in 799 mm drilling centerline 0 2 in 5 mm edge to drilling centerline 0 2 in 5 mm ...

Страница 19: ...e 19 KayakDD 2 Installation Frame Measurements Figure 14 KayakDD 2 Frame Dimensions 8324_11_r0 19 0 inch 482 mm 17 2 inch 438 mm 15 5 inch 401 9 mm 15 6 inch 420 74 mm 5 2 inch 132 95 mm 18 3 inch 465 mm 0 3inch 7 5mm 2 25 inch 57 15mm ...

Страница 20: ...KayakDD 2 Rack Mounting CAUTION Mounting using only the front rack angles is permitted for fixed installations Additional support like slide rails is required for mobile applications flight case OB van Slide rails Recommended for mobil applications Not part of delivery Air Flow Air Flow ...

Страница 21: ...IN 16 J 41 J 42 ANALOG J 44 J 43 grass valley 48V 5A max KAYAK 2 M E DIGITAL SWITCHER R 3S13 Prof Vid Equipm Listed J3 OUT 48V 1 6A J 45 J 46 J 47 J 48 J 49 J 50 IN 17 J 58 IN 25 J 51 IN 18 J 59 IN 26 J 52 IN 19 J 60 IN 27 J 53 IN 20 J 61 IN 28 J 54 IN 21 J 62 IN 29 J 55 IN 22 J 63 IN 30 J 56 IN 23 J 64 IN 31 J 57 IN 24 J 65 IN 32 INPUT 17 32 This device complies with part 15 of the FCC Rules Oper...

Страница 22: ... KayakDD production switcher Power output is sufficient for two KayakDD 1 systems or one KayakDD 2 system Note To ensure sufficient RAM Recorder buffer voltage the cable length is limited to 20 m Standard KayakDD cables are not suitable for buffer voltage supply Installation Figure 17 KDD PSU Rack Installation Cut fastening metal so that the ventilation openings are not covered 8324_14_r0 ...

Страница 23: ...Signal Ground 5 Not used Not used 6 Signal Ground Signal Ground 7 RxB TxB 8 TxA RxA 9 Chassis Ground Chassis Ground Socket Pin Signal 1 Chassis Ground 2 Transmit Data 3 Receive Data 4 Not used 5 Signal Ground 6 Not used 7 Clear to Send 8 Request to Send 9 Not used Socket Pin Signal A1 48 V A2 48 V 1 2 3 4 5 Pin 1 Pin 5 Pin 6 Pin 9 D 9 Female Pin 1 Pin 5 Pin 6 Pin 9 D 9 Female Pin A2 Pin 2 Pin 1 Pi...

Страница 24: ...ted in the plug of the external power supply unit Frame DC Power Out Socket Pin Signal A1 48 V A2 48 V 1 Ground 2 Return Sense 3 7 V RAM Rec 4 5 48V Return Table 2 Socket Pin Signal A1 48 V A2 48 V 1 2 3 4 5 Pin A2 Pin 2 Pin 1 Pin A1 Pin 5 Pin 3 D Sub Male Pin A1 Pin 1 Pin 2 Pin A2 Pin 3 Pin 5 D Sub Female ...

Страница 25: ...7 GPIOut7B 20 40 GPIOut8B 21 24 GPIOutComC 22 8 GPIOut9C 23 41 GPIOut10C 24 25 GPIOut11C 25 9 GPIOut12C 26 42 GPIOutComD 27 26 GPIOut13D 28 10 GPIOut14D 29 43 GPIOut15D 30 27 GPIOut16D 31 11 GPIOutComE 32 44 GPIOut17E 33 28 GPIOut18E 34 12 GPIOut19E 35 45 GPIOut20E 36 29 GPIOutComF 37 13 GPIOut21F 38 46 GPIOut22F 39 30 GPIOut23F 40 14 GPIOut24F 41 47 GPIOutComG 42 31 GPIOut25G 43 15 GPIOut26G 44 4...

Страница 26: ...ol Panel Width 809 mm 31 8 inch Depth 418 mm 16 5 inch Mounting Depth 33 81 mm 1 3 3 2 inch Weight 10 kg 22 lb KDD PSU Power Supply Option Frame Height 1RU 44 mm 1 73 inch Width 482 mm 19 inch Depth 240 mm 9 45 inch Weight 2 8 kg 6 2 lb Table 4 Environmental Storage temperature 20 C to 70 C 4 F to 158 F Operating temperature 5 C to 40 C 41 F to 104 F Relative humidity 95 non condensing Electromagn...

Страница 27: ... 2 Frame Line voltage 100V 240V AC 10 autorange power factor corrected 48V 5A DC Input for ext redundancy Line frequency 50 60Hz 5 Power consumption max 250W max 310W with 48V DC supply for panel Leakage current 2 mA RAMRecorder buffer voltage 6 8V DC approx 150 mA DC OUT for control panel 48V DC max 1 6A KayakDD 2 Control Panel DC IN 48V DC In max 1 3A Power consumption max 60W KDD PSU Frame Line...

Страница 28: ...nput Impedance 75 ohm Max cable length 225 meters 738ft Table 8 Serial Digital Video Outputs Format ITU R656 270Mbit s Number of Outputs KayakDD 1 15 KayakDD 2 20 Return loss 15dB 5 270MHz Type of Connector 75 ohm BNC SMPTE 259M Nominal Amplitude 800mV peak to peak 10 SMPTE 259M Rise Fall Times 400 to 1400picoseconds 75 ohm termination between 20 and 80 amplitude Jitter ITU R 601 656 Output Impeda...

Отзывы: