DFT-6900 Battery Activator Instruction Manual
13
Chapter 4 FAQ
Do not start up
Check power supply wiring
No signals after the Tester is on
The Tester may not be properly connected. If so, make sure it is well connected.
Activator for N times charge/discharge alone
Since the duration of charge and discharge alone should not exceed 18 hours, if it is required to charge and
discharge for more than 18 hours, use N cycles to prolong the time. Example: If the charging required time is 28
hours, set the activation cycle: 2, the first charging time is 18 hours, the discharge duration is 0, the second
charging time is 10 hours, and the discharge duration is 0. The long time discharge method is the same as above,
and the charging time should be 0.
Battery No. Setting
There are 4 digits for battery number. In order to facilitate management, the first two digits are for battery group
number, the last two digits are for the battery number, and there are up to 99 Strings, and the maximum number of
batteries in the same group is 99.