![THOMSON DFT-6900 Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/thomson/dft-6900/dft-6900_user-manual_1108864009.webp)
DFT-6900 Battery Activator Instruction Manual
8
2.
3 Activator
Click “Activator” to enter parameters setting interface
2.3.1 Activator Setting Interface
In the activation setting interface, the battery number, battery type, rated capacity, discharge voltage limit, charge
limit voltage, and number of cycles (the number of times is not more than 10) are displayed. As shown below:
Enter the battery activation interface. As with the charge/discharge function settings, the battery type must be
selected before the activation parameter setting is performed: 2V battery / 6V battery / 12V battery. The activation
settings interface is as follows:
After clicking the up and down direction keys to set the "Cycle No.", you can set the parameters of each
activation by clicking the page up and page down. The setting parameters: cutoff voltage, current, capacity and
duration.
2.3.2 Activating Process
The activating process includes discharging & charging (please refer to “Discharge” & “Charge”): press the [Back]
key to interrupt the activation.
2.4 Data Management
Test results can be viewed, exported, deleted, and formatting in the Data Management menu. Data
management includes discharge measurement data, charge measurement data, and activation measurement data.
2.4.1 Data Review
In the main menu, enter “Data Management”, select the data type, select the data, and press the [View] key to