Symptom
Remedy
The unit does not work, no light.
Check the mains connection and the main fuse.
No response to the DMX con‐
troller.
1. If the unit is in DMX mode and a DMX controller is
connected and turned on, the
‘d’
flashes in the first posi‐
tion of the display. If not, no valid DMX signal is received.
Check that the DMX controller is switched on. Check the
DMX connectors and cables for proper connection.
2. If the display is not flashing and there is still no
response, check the address settings and DMX polarity.
3. Try using another DMX controller.
4. Check to see if the DMX cables run near or alongside
to high voltage cables that may cause damage or inter‐
ference to DMX interface circuits.
No response to the remote con‐
trol
1. Try the remote control at a different angle to the
receiver on the front of the device.
2. Move the remote control closer to the unit.
3. Check the remote control battery.
Troubleshooting
Quad Par Profile 5x8W RGBW 5x8W RGB WW
61
Содержание Stairville Quad Par Profile
Страница 1: ...Quad Par Profile 5x8W RGBW 5x8W RGB WW LED PAR user manual...
Страница 24: ...6 Connections and operating elements Overview Connections and operating elements LED PAR 24...
Страница 26: ...1 2 3 DMX Out Power Out Top side Connections and operating elements LED PAR 26...
Страница 28: ...USE ONLY WITH A 250 V FUSE Power In DMX In Bottom Connections and operating elements LED PAR 28...
Страница 30: ...Mode Setup Up Down 0 Operating elements at the side Connections and operating elements LED PAR 30...
Страница 66: ...Notes LED PAR 66...
Страница 67: ......
Страница 68: ...Musikhaus Thomann Hans Thomann Stra e 1 96138 Burgebrach Germany www thomann de...