DIP-Switch (6-pole)
Black Design
OPEN
1 2 3 4 5 6
CLOSED
DIP-Switsch (6-pole)
Red Design
ON
1 2 3 4 5 6
OFF
PC-board
or
Figure 3: DIP- switch
DIP-Switch, black design
DIP-Switch, red design
Measuring Range
DIP-switch 1
DIP-switch 2
DIP-switch 1
DIP-switch 2
10 mm *
CLOSED
CLOSED
ON
ON
20 mm
OPEN
CLOSED
OFF
ON
25 mm
CLOSED
OPEN
ON
OFF
50 mm
OPEN
OPEN
OFF
OFF
Gliding Period
DIP-switch 3
DIP-switch 4
DIP-switch 3
DIP-switch
10 min
CLOSED
CLOSED
ON
ON
60 min
OPEN
CLOSED
OFF
ON
6 h
CLOSED
OPEN
ON
OFF
24 h
OPEN
OPEN
OFF
OFF
Signal Processing
DIP-switch 5
DIP-switch 5
Accumulating precipitation sum *
CLOSED
ON
Gliding precipitation sum
OPEN
OFF
Offset-Function
DIP-switch 6
DIP-switch 6
0-20 mA / 0-10V / 0-5V
CLOSED
ON
4-20 mA / 2-10V / 1-5V
OPEN
OFF
Table 3: set from DIP- switch
= factory adjustmen
12 - 18
021326/05/10